Set Up - Selecting The Mode For Acquiring Wheel Dimensions In The Alu1 And Alu2 Balancing Programmes; (Only The Machine Version With Manual Sensor) - Corghi CompactLine EM 9250 Manuel D'utilisation

Masquer les pouces Voir aussi pour CompactLine EM 9250:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Important
the wheel must be fixed to the flange so as to avoid any movement of the two during the
spin or braking phases.
Best results can be achieved if the adhesive weights are positioned with the outer edge
flush with the rim edge.
15.2. SET UP – SELECTING THE MODE
FOR ACQUIRING WHEEL DIMENSIONS
IN THE ALU1 AND ALU2 BALANCING
PROGRAMMES (ONLY THE MACHINE
VERSION WITH MANUAL SENSOR)
This configuration is used to select the method for entering dimensions for the ALU1 and
ALU2 programs and as a result the method of applying the adhesive weights inside the rim.
Proceed as follows to recall this programme:
- press the
key
- use the
- press the
key to confirm
- use the
- press the
key to change the setting:
or ALU P: to activate the ALUP balancing programmes. These programmes are used for
maximum precision balancing on light aluminium rims that require the application of both
weights on the same side (inner) in relation to the rim disk. This type of wheel balancer is
particularly suitable for application of adhesive weights on the rim, thanks to the forward
position of the wheel in relation to the body, which allows a large zone on the inside of
the rim to be accessed freely. To enter the dimensions and apply the weights, refer to the
paragraphs with ALU 1P – ALU2P
or ALU St: to memorise the rated dimensions of the rim. Self-adhesive weights are gener-
ally used to balance alloy wheels and are applied differently than for standard balancing.
Several ALU balancing programmes are available, specially designed for these types of rim.
To enter the dimensions and apply the weights, refer to the paragraphs "Entering wheel
dimensions (ALU1P and ALU2P programmes excluded)" and "Applying balancing weights"
EM 9250 - EM 9250 C CompactLine Operator's manual
keys to search for SEt UP
keys to search for ALU P (or ALU St if previously set)
UK