CAUTION
This key is deactivated if the gram by gram unbalance display has been set in the ma-
chine set up or if the ALU1P or ALU2P balancing programme is used.
8. BALANCING WEIGHT APPLICATION
• clip weights
- Select the first side to be balanced.
- Turn the wheel until the central element of the corresponding position indicator lights
up.
- Apply the indicated balancing weight in the position of the rim corresponding to 12
o'clock.
CAUTION
Check that the system which fits the weight to the rim is in optimum condition.
A weight which is not fitted properly or correctly may come off as the wheel rotates, thus
creating a potential danger.
Pressing the
time and the A STP message is displayed.
If the "RPA" (centred position) programme is active, at the end of each balancing spin the
machine stops the wheel in the position for application of the weight on the outer side; if it
is equal to zero, the wheel is stopped in the inner side weight application position.
Pressing the
position is activated.
This function is described at length in the AUTOMATIC POSITION SEARCH section.
• Manually applied adhesive weights
- Select the first side to be balanced.
- Turn the wheel until the central element of the corresponding position indicator lights
up.
- Apply the indicated balancing weight in the position of the rim corresponding to 12
o'clock.
WARNING
The application position of the adhesive weight can be changed from 12 o'clock to 6 o'clock
by following the instructions in the set up menu "Adhesive weight application position ".
WARNING
- for applying the adhesive weight in the MOTORCYCLE (ALU) programmes, always use 12
o'clock as the reference regardless of the setting in "SELECTION OF ADHESIVE WEIGHT
EM 9250 - EM 9250 C CompactLine Operator's manual
button while the wheel is moving interrupts the wheel spin before
button with the guard raised, automatic search for the second side
UK