Corghi CompactLine EM 9250 Manuel D'utilisation page 141

Masquer les pouces Voir aussi pour CompactLine EM 9250:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

E 3 I/E 2/3 Error condition at the end of sensitivity calibration. Repeat the calibration, if the
message persists perform the following checks:
Correct sensitivity calibration procedure;
Correct fastening and position of the calibration weight;
Mechanical and geometric condition of the calibration weight;
geometry of the wheel used.
E 4
a) External mechanical sensor calibration error condition. Perform the external
mechanical sensor calibration procedure.
b) if the error continues after calibrating the external sensor or the external sen-
sor is not present, or there is a distance-diameter measuring sensor fault, call the
technical support centre.
E 4
a) Error condition on ultrasonic sensor calibration. Calibrate the ultrasonic sensor.
b) ultrasonic sensor not present. Visualisation of this error can be disabled by
performing the following procedure:
press the
use the
press the
E 6
Error condition when executing optimisation programme.
Repeat the procedure from the beginning.
E 12
a) Mechanical width sensor not in the rest position when machine was switched on.
Switch off the machine, return the sensor to the correct position and switch back
on. If the error persists, call in the technical support centre.
b) External sensor not present or faulty. Visualisation of this error can be disabled
by performing the following procedure:
• press the
• use the
• press the
E 12
Ultrasonic width sensor not present or faulty. Visualisation of this error can be
disabled by performing the following procedure:
• press the
EM 9250 - EM 9250 C CompactLine Operator's manual
key
keys to search for GAU CAL
key
key
keys to search for GAU CAL
key.
key
UK
141

Hide quick links:

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Compactline em 9250 c

Table des Matières