Elixo Smart io

3. USE AND OPERATION

3.1. Normal operation

3.1.1. Using Keygo io type remote controls
Complete opening
Press the programmed button to open the gate fully.
Pedestrian opening
Press the programmed button to open the gate in pedestrian mode.
Closing
Stop
3.1.2. Obstacle detection operation
• When an obstacle is detected during opening, the gate will stop then
close again.
• If an obstacle is detected during closing, the gate will stop then open
again.
Copyright © 2018 SOMFY ACTIVITES SA. All rights reserved.
STOP
STOP
STOP
STOP
STOP
STOP

3.2. Specific operation

Depending on the additional devices installed and the operating options
programmed by your installer, the motorisation may operate in the
following specific ways:
3.2.1. Operation with a 3-button remote control
STOP
STOP
3.2.2. Operation with safety cells
An obstacle placed between the cells will prevent the gate from closing.
If an obstacle is detected while the gate is closing, it stops, then re-opens
fully.
If an obstacle is detected when opening, the gate will continue to open.
STOP
If the cells are blocked for 3 minutes or more, the system switches to
STOP
"wired dead man" operating mode. In this mode, a command via the wired
input causes the gate to move at reduced speed. The movement lasts as
long as the command is maintained and stops as soon as the button is
released. The system switches back to normal mode as soon as the cells
are no longer blocked.
STOP
Attention
the "wired dead man" mode requires the use of a safety contact
(e.g. keyed reversing switch ref. 1841036).
3.2.3. Operation with orange flashing light
The orange light is activated 2 s before the gate begins moving if the gate
is in sequential mode with automatic closure after a time-delay.
3.2.4. Area lighting operation
Area lighting comes on with the motor, and goes out 60 seconds after the
motor has come to a complete stop.
If a remote control is programmed to control the lighting, it operates as
follows:
With a 2 or 4 button remote control
With a 3-button remote control
STOP
STOP