1.2.c. Electrical and pneumatic
connections
The electrical power line connecting the
machine must be suitably sized in rela-
tion to:
• the electric power absorbed by the ma-
chine, indicated on its data plate (Fig. 1);
• the distance between the machine and
the electric hook-up point, so that voltage
drops under full load do not exceed 4%
(10% when starting up) of the rated voltage
specifi ed on the data plate.
- The user must:
• fi t a power plug on the power supply
lead in compliance with the relevant safety
standards;
• connect the machine to its own electrical
connection - A, Fig. 2 - and fi t a differential
safety circuit-breaker with 30 mA residual
current;
• install protection fuses on the power line
that are suitably sized in accordance with
the indications provided on the machine
data plate (Fig. 1);
• connect the machine to an industrial so-
cket; the machine must not be connected
to domestic sockets.
An effective grounding connection is essential for correct operation of the machine.
Make sure the available pressure and the rendered capacity of the compressed air system
are compatible with those required for correct machine operation - see the "Technical Data"
section. For correct machine operation, the compressed air supply line must provide a
pressure range from no less than 8.5 bar to no more than 16 bar and guarantee an air fl ow
rate greater than the average consumption of the machine, which is equal to 160 Nl/min.
For the machine to function correctly, the compressed air delivered suitably must be
suitably treated (not above 5/4/4 in accordance with ISO 8573-1).