Mondolfo Ferro Aquila Tornado Manuel D'utilisation page 192

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Keep the working area clean. Do not use compressed air, jets of water or thinner to re-
move dirt or residuals from the machine. While cleaning, try as far as possible to prevent
dust from forming or rising.
MONDOLFO cannot be held responsible in the event of any damage caused by using
non-original spare part or accessories.
SCHEDULED MAINTENANCE:
- Periodically check the level in the hydraulic power unit. The tank is made out of
transparent plastic and is located inside the protective casing (fi g. 56).
Proceed as follows:
- unscrew the 4 screws on the casing;
- check that the oil level in the tank is between the MINIMUM and MAXIMUM arrows
(fi g. 56a);
- if necessary, unscrew the tank plug and top up using Esso NUTO H 46 hydraulic oil or
equivalent (e.g: AGIP OSO 46, SHELL TELLUS OIL 46, MOBIL DTE 25, CASTROL HYSPIN
AWS 46, CHEVRON RPM EP HYDRAULIC OIL 46, BP ENERGOL HLP);
- retighten the tank plug and remove the protective casing.
192
WARNING
CAUTION!
56
User manual Aquila Tornado
56a

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

4-119239b

Table des Matières