1.2.d Technical data
- Tire types processed .CONVENTIONAL - LOW PROFILE - RUN FLAT - BALOON BSR
- Wheel dimension range:
• rim diameter ................................................................................................ from 13" to 32"
• maximum tyre diameter ....................................................................................... 1200 mm
• maximum tyre width ...................................................................................... 400 mm (16")
- Turntable:
• automatic positioning in relation to ........................................................................... tools
• resting side ................................................................................................................fl anged
• centring ..................................................................................................................... on cone
• automatic ................................................................................................................ clamping
• drive system .......................................................................... 2-speed motor-inverter unit
• torque ......................................................................................................................1200 Nm
• rotation speed ........................................................................................................7-20 rpm
- Wheel lifter:
• lifting capacity .............................................................................................................. 85 Kg
- Power supply:
• 1 Ph mains power ...........................................................................................230V-50/60Hz
• 1 Ph mains power (alternative) .....................................................................110V-50/60Hz
• hydraulic unit motor ............................................................................................ 0.6-0.8 kW
• hydraulic operating pressure .................................................................................. 120 bar
• pneumatic operating pressure: ............................................................................8 -10 bar
• min. rated air delivery rate: .............................................................................. 160 Nl/min
- weight with lift s.l. ...................................................................................................................500 kg
- weight with lift p.l ....................................................................................................... 550 kg
- Weight of electric/ electronic parts ................................................................................ 49 kg
- Noise level:
• Weighted sound pressure level A (L
The noise levels indicated correspond to emission levels and do not necessarily repre-
sent safe operating levels. Although there is a relationship between emission levels and
exposure levels, this cannot be used reliably to establish whether or not further precau-
tions are necessary. The noise levels to which the operator is exposed to depends on a
number of factors, such as duration of exposure, characteristics of the workplace, other
sources of noise etc. Permissible noise exposure limits may also vary from country to
country. However, this information will enable machine users to make a more accurate
assessment of hazard and risks.
User manual Aquila Tornado
) in the work place .............................< 70 dB(A)
pA
127