- Relative humidity from 30% to 95% without condensation.
Temperature range from 0 C to 50 C.
-
ATTENTION
The machine must not be operated in potentially explosive atmosphere.
WARNING
All operations required for the electrical hook-up of the machine must be carried out exclusively
by a qualified electrician.
- The electrical supply must be suitably sized in relation to:
• absorbed power specifications indicated on the machine dataplate.
• the distance between the machine and the power supply hook-up point, so that voltage drops under full load do not
exceed 4% (10% in the case of start-up) below the rated voltage specified on the dataplate.
- The user must equip the machine with the following:
• a dedicated power plug in compliance with the relevant electrical safety standards;
• a type A and B suitable circuit-breaker (residual current set to 30 mA) on the mains connection;
WARNING: only a type A and B differential security breaker of the specified kind
response to all the failure currents which may occur on the machine.
• power line fuses in accordance with specifications in the main wiring diagram of this manual;
• a suitable earthing system installed on the workshop mains line.
- To prevent unauthorised use of the machine, always disconnect the mains plug when the machine is not used
(switched off) for extended periods of time.
- If the machine is connected directly to the power supply by means of the main electrical panel and without the use of a
plug, install a key-operated switch or suitable lock-out device to restrict machine use exclusively to qualified personnel.
For correct operation of the machine the compressed air supply line must provide a pressure range from a minimum of
8 bar to a maximum of 16 bar.
NOTE
The machine is equipped with a pressure regulator set at 10 bar (standard machine operation). If you are working with
easily deformable rims (motor cycle wheels for example) we recommend lowering the pressure temporarily to 7 or 8
bar.
ATTENTION
For correct and safe operation of the machine it must be connected to an efficient grounding
circuit.
NEVER connect the ground wire to a gas pipe, water pipe, telephone line or other makeshift
system.
Before making the electrical and pneumatic hook-ups, make sure that the machine is configured as described below
(fig.5):
- pedals A in the "fully down" position and B in the "fully up" position;
- tower C vertical (not tilted).
The equipment is intended for professional use only.
WARNING
Only one operator may work on the equipment at a time.
WARNING
Failure to observe these instructions and the relative danger warnings can cause serious injury
to the operator and others. Do not power up the machine before you have read and understood
all the danger/warning/attention notices in this manual.
Ambient conditions in the place of operation
ELECTRICAL AND PNEUMATIC HOOK-UPS
SAFETY REGULATIONS
26
will be tripped correctly in