Operating Logic - Aprimatic R1-24 Notice D'installation Et D'entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Operating logic

SEMIAUTOMATIC MODE WITH STOP (
Starting with the gates closed:
START pulse
the wings open and the gates stays stopped in the open position
the gate.
The START pulse during opening stops the wings
The START pulse during closing
4
STEP-BY-STEP MODE (
Starting with the gates closed:
START pulse
the wings open and the gates stays stopped in the open position
the gate.
The START pulse during opening stops the wings
The START pulse during closing stops the wings
5
MANNED MODE (
)
Manned mode requires the presence of an operator to operate and stop the gate by pressing and releasing the START
button.
Repeatedly pressing the START button causes alternate opening and closing.
Starting with the gate closed, the complete operating cycle is as follows:
START pulse
the gate opens and moves until START is pressed and held or until the gate is fully open.
safety device triggered during opening
next START pulse
the gate moves in the opposite direction (CLOSES) and continues to move until START is pressed
and held or until the gate is fully closed.
photocell triggered during closing
6
TIMER MODE (
)
Timer mode ensures the gate remains open when the START pulse is pressed and held. The gate closes when the
START button is released.
legend:
: locks and inhibits signals until a START command
1
locks
: locks until a START to close
2
locks
: locks until a START command to close ignoring pause time
3
locks
: locks as long as the photocell is covered, ignoring pause time
4
locks
5
: if the START command is given within the fi rst 3 seconds of the opening pause, will lock until a new START command to close
locks
is given
: locks if the photocell is covered and then closes
6
locks
: locks as long as the photocell is covered; when the photocell is uncovered will complete the movement
7
locks
8
: LOCKS until a new START command is given and then opens
locks
9
: the START command is inhibited as long as the photocell is covered then closes
locks
: closes ignoring the pause time
1
closes
: reopens slowly
1
re-opens
: LOCKS until a new START command is given and then opens slowly
2
re-opens
3
)
opens the wings.
)
movement stops until the signal is disabled (or the button is released).
movement stops until the signal is disabled (or the button is released).
another START pulse will close the wings.
another START pulse will close the wings.
another START pulse opens the wings.
- 30 -
another START pulse will close
another START pulse will close

Publicité