Programmable Parameters; Display Function - Aprimatic R1-24 Notice D'installation Et D'entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Basic and advanced programming
4.3

PROGRAMMABLE PARAMETERS

DISPLAY
FUNCTION
Logic
0 = Automatic; 1 = 4 steps; 2 = Super automatic;
LO
3 = Semi-automatic with stop; 4 = Step-by-step;
5 = Manned; 6 = Timer (start input)
PA
Pause time (0"- 60") (1 step =1")
En.
Force (thrust force on obstacle) (0 = overridden)
SPE.
Wing speed (0=50% ; 1=70% ; 2=85% ; 3=100% maximum speed)
ElS.
Electric lock (0=disabled; 1=enabled)
LAm.
Pre-fl ashing time (0"- 9") (1 step =1")
PSET
Restore factory settings (default)
PRoF
To enter programming mode
A1
Wing 1 delay during closing (0°-75°) (1 step = 5° displacement approx.)
A2
Wing 2 delay during opening (0°-10°) (1 step = 2.5° displacement approx.)
A3
Pedestrian wing opening (20% - 100%) (1 step = 20%)
A4
Electric lock operation time (3.0"- 5.0") (1 step = 0.5")
A5
Electric lock advance (0" - 1") (1 step = 0.5")
A6
Reverse stroke time (0"- 2") (1 step = 0.5") with autoset 1" if electric lock fi tted
A7
Obstacle masking time at start-up (3"- 6") (1 step = 0.5")
Reverse time at end of movement (0mSec- 400mSec) (1=30; 2=50;
A8
3=80; 4=100; 5=120; 6=150; 7=200; 8=300; 9=400)
A9
Approach speed (50% - 80% cruising speed) (1 step = 10%)
AA
Start ramp incline (0 = max acceleration; 4 = minimal acceleration)
Ab
Brake ramp incline (0 = max brake; 4 = minimal brake)
Ac
Approach distance (5°-22,5°) (1 step = 2.5°)
Closing when the photocell is no longer covered occurs:
00= immediately
Ad
01= at the end of the pause time (counting continues)
02= after 10"
03= after a complete new period of pause time (reloads the pause time)
AE
-
Emergency functioning with batteries in the event of mains power failure
(slow wing speed, increased fl ashing light speed)
AF
00 = the gate can perform 3 cycles and then stops functioning
01 = the gate can perform 3 cycles and then stops open
02 = the gate opens and stays open (safety functioning)
Flashing light ON during pause time
AH
00 = disabled (only automatic functioning); 01 = enabled
AM
-
Windproof: recovery of structure elasticity in case of pressure changes (wind)
At
0 = disabled; 1 = enabled
Ap
-
Ar
Safety device during opening: (00 = safety edge; 01 = photocell)
AU
Self adjusment (0=disabled ; 1=enabled)
ALt
Shows the total number of counter opening operations (1 step =100 cycles).
Shows the number of counter maintenance partial operations (x 10 cycles).
ALP
Flashing if in OVERFLOW.
Sets the counter maintenance cycle (x 10 operations) with minimum step of
ALS
100 operations. Each setting resets the maintenance cycle (ALP).
ALr
Resets the maintenance counter.
IMPORTANT NOTE:
Blue
To select
- 28 -
Red
Yellow
To confi rm
To exit
VALUES
DEFAULT
0.
0 - 6
(automatic)
25.
0 - 60
0 - 5
0 - 3
0.
0 - 1
(disabled)
0 - 9
Red button to confi rm
Red button to confi rm
05.
00 - 15
(approx 25°)
02.
01 - 05
(approx. 5°)
04.
00 - 04
(opens everything)
3.0.
3.0 - 5.0
0.5.
00 - 1.0
0.0.
0.0 - 2.0
3.0.
3.0 - 6.0
00.
00 - 09
(disabled)
01.
00 - 03
02.
00 - 04
02.
00 - 04
03.
02 - 09
01.
00 - 03
(at the end of the
pause time)
-
00.
00 - 02
(3 cycles can be
performed)
00.
00 - 01
(disabled)
-
-
-
01.
00 - 01
(photocell)
0.
0 - 1
(disabled)
0000-9999
0000-9999
00.00
0000-9990
(no maintenance)
-
2.
2.
3
(3.0")
(disabled)
(60%)
(7°)
-
-
-
-
-
-
-

Publicité

Table des Matières
loading

Table des Matières