SETTING THE TEMPERATURES

8
The variation of the settings of the control
unit can be done only by experienced tech-
L6
L1
L2
L3
nicians. It is recommended not to change
L5
L4
L6
L6
L1
L2
the factory settings if it is not necessary for
L3
L5
L5
L4
L6
L1
L2
L3
L5
L4
• The button
select the temperature to be changed
• The buttons
allow to change the value
• The button
saves the variation or button
Other parameters can be changed by entering in the installer menu.
Description
A01
Thermostat pump (°C)
A02
Thermostat valve (°C)
A03
Thermostat AUX (°C)
A05
Thermostat Serv (°C)
Table 3 - Default settings in the main menu.
4.5
FUNCTIONS OF THE UNIT
Basically, the electronic unit checks the
working of the heating system; in addition,
it has also other auxiliary and safety func-
tions.
Main function - The unit reads the water
temperature of the boiler, when it exceeds
the set temperature, the unit starts the cir-
culation pump of the heating system. When
the temperature goes under the set value,
the pump stops, allowing the temperature
to go up again.
Secondary functions - When the tempera-
ture exceeds the set values (A02, A03, A05),
the correspondent clamps activate (Valve,
L6
L5
L1
L2
L3
L4
will show the
6
4
7
2
5
8
L1
L2
L3
L4
Standard value
95
L1
L2
L3
L4
external 3 ways electro-valve, as thermostat
for the deactivation of a potential external
heat generator, and as thermostat for a po-
tential other device not specified.
the working of the heating system. The var-
iation of the set temperatures may be done
in the main menu.
L6
L1
L2
L3
L5
L4
delete the change
Corresponding LED
55
60
40
50
Aux, Serv) and then the potential external
connected devices. According to the instal-
lation, they could not deal with the normal
use of the thermal cooker.
Sanitary function - When the sanitary hot
water function is required, the presence of
the liquid flow is detected, so the heating
system pump stops and gives prevalence to
the sanitary hot water. The pump restarts it
the temperature exceeds the temperature
set as safety thermostat.
Alarm function - If the temperature ex-
ceeds the set value for the alarm thermo-
stat, an acoustic and visible signal will be ac-