Additional clearances
Check to determine whether local codes supersede
these clearances.
Avoid termina on loca ons near a dryer vent.
Avoid termina on loca ons near commercial
cooking exhaust.
You must install a vent termina on at least 12
inches above the ground or anticipated snow
level if higher.
RUR98i
The vent for this appliance shall not terminate
Over public walkways; or
Near so t vents or crawl space vents or other
area where condensate or vapor could create a
nuisance or hazard or cause property damage; or
Where condensate or vapor could cause damage
or could be detrimental to the operati n of
regulators, relief valves, or other equipment.
Important considerati ns for locati g vent
termina on under a so t (ven lated or unven lated
or eave vent; or to a deck or porch)
Do not install vent termination under a so t vent
such that exhaust can enter the so t vent
Install vent termina on such that exhaust and rising moisture
will not collect under eaves. Discolora on to the exterior of
the building could occur if installed too close.
Do not install the vent termina on too close under the so t
where it could present recircula on of exhaust gases back
into the combus on air intake part of the termina on.
(0.30 m ) to
an inside
corner
36"
12"
V
12"
INSIDE
CORNER
V
(0.30 m) between
terminals at same
level
KBP Series Manual
(50 mm) between
terminals at same level
12"
(0.30 m) to an
inside corner
(1.52 m)
between
terminals at
diff rent levels
V
(1.52 m)
vertica ly
between
60"
terminals
V
RUR98e
(0.91 m) to ven lated
or unven lated so t
or eve vent; or to a
36"
deck or porch
2"
(1.52 m) vertica ly
between terminals
60"
60"
V
V
(0.61 m) to wall or parapet
24"
V
12"
(0.30 m) between
V
V
terminals at same
level