Certi d PVC/CPVC Vent Termination Op ons (conti ued)
3" and 4" Low Profile Vent Termina on Kits
The following informati n should be used in conjunc on
with the IPEX System 636 Installatio Guide:
Terminati n kits are to be tested and certified for use
with the brand of pipe-fi
be uti ized in the applicati n. The IPEX Low Profi e
terminati n is fully certi d for use with IPEX product
only.
System 636 PVC Low Profi e Vent kits are rated to 65°C
maximum and are made from certi ed compound.
All terminatio kits must be located and installed in
accordance with these instructio s, local building code,
and CSA B149.1 Natural Gas and Propane Installatio
Code.
Installati n:
1.
Once a proper locatio has been determined, cut 2
appropriately sized holes in the wall to accommodate
the pipe. (Reference the Low Profil Terminatio
Kit-Dimensions table below)
2.
Slide intake and exhaust pipes through the holes.
Secure (using required solvent cement) both pipes to
the base of the vent termina on kit. (Be sure to follow
guidelines for solvent cemen ng as described in the
System 636 Installatio Guide)
3.
Use the supplied screws and anchors to secure the
base to the wall. (a drilled 3/16" hole, 1-3/16" deep
will be needed for the anchors.) Use the base as a
template to locate the anchor hole.
4.
Using the supplied screws, secure the Cap to the Base.
5.
Upon securing the vent terminati n and pipes, seal the
wall penetratio s (from the interior) using a PVC
compati le sealant material.
WARNING
All exhaust vents and air inlets must terminate at the same
height to avoid property damage, personal injury, or death.
Low Profi e Terminati n Kits-Dimensions
Item #
Descrip on
196985 3" Flush Mount
196986 4" Flush Mount
g-cement system that is to
Pipe Outside
Hole Spacing
Diameter
3.5"
5.6"
4.5"
5.6"
KBP Series Manual
Kit Contents
Qty
Item Descriptio
1
Base (Two Holes)
1
Cap (One Hole)
8
Stainless Steel Screws
4
Plas c Anchors
To Water Heater Intake Air
Connecti n
From Water Heater Vent
Pipe Connec on
Orienta ons
Vent / Air
Termina on
Air Piping
Vent Piping
Vent
Vent / Air
Termina on
12" min
Grade or
Snow Line
Vent Base
Vent Cap
12" Min Between Edge of Air
Inlet and Adjacent Vent Outlet
Air
31