Rinnai RUR98i Mode D'emploi page 44

Publicité

Cross Over Mode
Cross over mode requires a thermal bypass valve
(included); Refer to Installa on of Plumbing sec on
(Cross Over Mode Plumbing Diagram)
Thermal Bypass Valve:
Thermal bypass valve is installed between hot and
cold line on furthest xture (ie. end of
domestic water supply).
The valve helps regulate ow from the hot water
line to the cold water line allowing for quicker
delivery of hot water.
No more than 1 thermal bypass valve should be
installed per water heater.
Refer to thermal bypass valve instructi ns for fur-
ther informa on.
(Recirculati n using cross over mode may result in
combustio icon switching ON and OFF several times,
this is normal.)
Thermal Bypass Valve
Maximum Pipe Length*
Pipe Diameter
Short Loop
Long Loop
(*Take equivalent elbow lengths into consideratio when
calculati g pipe length.)
Cross Over Mode Pump Intervals
Pump Status
ON
OFF
* The pump will cycle ON and OFF at these intervals. These intervals are calculated based on the insulatio , loop length, and
es mated heat loss in the system.
44
3/4"
1/2"
200
50
400
100
Long loop Mode (201 - 400 )
Economy
Comfort
KBP Series Manual
Dip Switch setti s for Cross Over Mode (DIPSW 2)
Operatio
Pump OFF
Short Loop
Economy Mode
Short Loop
Comfort Mode
Long Loop
Economy Mode
Long Loop
Comfort Mode
Typical Intervals (minutes)
Short loop Mode (Up to 200 )
16
10
4
SW 4 in
SW 7 in
DIPSW2
DIPSW2
OFF
OFF
ON
ON
ON
ON
ON
OFF
ON
OFF
8
10
4
SW 8 in
DIPSW2
OFF
OFF
ON
OFF
ON