Rinnai RUR98i Mode D'emploi page 75

Publicité

Code
Defi iti n
19
Electrical Grounding
Condensate Trap is full
25
31
Burner Sensor
Outgoing Water
32
Temperature Sensor
Heat Exchanger Outgoing
33
Temperature Sensor
Outside Temperature
41
Sensor
Inlet Water Temperature
51
Sensor
Modula ng Solenoid Valve
52
Signal
57
Burner
58
Secondary heat exchanger
61
Combus on Fan
63
Circula on Pump
65
Water Flow Control
70
PC Board
71
Solenoid Valve Circuit
72
Flame Sensing Device
73
Burner Sensor Circuit
Scale Build-up in Heat
LC #
Exchanger (when checking
(LC0,
maintenance code history,
LC1,
"00" is subs tuted for
LC2,...)
"LC")
Maintenance has been
FF
performed
Nothing happens when
No
code
water flow is ac vated.
Remedy
licensed
professional
Check all components for electrical short.
only
Check condensate trap and drain line for blockage.
Replace condensate trap.
Measure resistance of sensor.
Replace sensor.
Check sensor wiring for damage.
Measure resistance of sensor.
Clean sensor of scale build-up.
Replace sensor.
Check modula ng gas solenoid valve wiring harness for loose or damaged terminals.
Measure resistance of valve coil.
Contact a licensed professional.
There is scale build up in the secondary heat exchanger and it needs to be ushed to prevent
damage. Refer to the flushing instruc ons in the manual. Hard water must be treated to
prevent scale build up or damage to the heat exchanger.
Ensure fan will turn freely.
licensed
Check wiring harness to motor for damaged and/or loose connec ons.
professional
Measure resistance of motor winding.
only
Ensure cold water inlet and hot water outlet valves are open to plumbing.
Inspect/clean inlet lter for debris.
If applica on is using a cross-over valve inspect/clean pump lter.
If installed with dedicated return, inspect return line.
If draining pump, purge air from recircula on pipe before running a fixture.
If installed in a cold climate open a hot water fixture and run unit for 5 minutes.
Purge air from recircula on line by opening fixture furthest and/or highest from unit during
pump opera on.
Replace Pump.
The water flow control valve has failed to close during the bath ll func on. Immediately turn
off the water and discon nue the bath ll func on. Contact a licensed professional to service
the appliance.
Check PC board DIP switches for correct posi on.
Check the connec on harness at the connec on on the PC board.
Replace PC board.
Replace the PC Board.
Replace the PC Board.
Check sensor wiring and PC board to be sure that they have not been damaged.
Replace sensor.
LC0~LC9 indicates that there is scale build up in the heat exchanger and that the heat
exchanger needs to be ushed to prevent damage. Refer to the flushing instruc ons in the
manual. Hard water must be treated to prevent scale build up or damage to the heat
exchanger.
To operate the water heater temporarily un l the heat exchanger can be ushed, push the On/
Off bu on on the temperature controller 5 mes. Repeated LC codes will eventually lockout
the water heater.
Please call Rinnai technical department.
Indicates a licensed professional performed maintenance or corrected an issue.
Clean water filter(s).
On new installa ons ensure hot and cold water lines are not reversed.
Verify you have at least the minimum flow rate required to fire unit.
Check for cold to hot cross over. Isolate circula ng system if present. Turn off cold water to the
unit, open pressure relief valve; if water con nues to ow, there is bleed over in your plumbing.
licensed
Verify turbine spins freely.
professional
Measure the resistance of the water ow control sensor.
only
If the display is blank and clicking is coming from the unit, disconnect the water flow servo
motor (GY, BR, O, W, P, BL, R). If the display comes on replace the water ow servo motor.
KBP Series Manual
75