Rinnai RC80HPi Manuel D'installation Et D'utilisation
Rinnai RC80HPi Manuel D'installation Et D'utilisation

Rinnai RC80HPi Manuel D'installation Et D'utilisation

Chauffe-eau d'intérieur sans réservoir à ventilation directe
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

Register your product at www.rinnairegistration.com or
call 1-866-RINNAI1 (746-6241)
ANS Z21.10.3
CSA 4.3
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
WARNING: If the information in these instructions is not
followed exactly, a fire or explosion may result causing
property damage, personal injury or death.
- Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in
your building.
Immediately call your gas supplier from a neighbor's phone.
Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire
department.
- Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
Direct Vent Tankless Water Heater
Operation and Installation Manual
FOR INDOOR APPLICATIONS ONLY
RC80HPi ............. REU-KA2530FFUD-US
RC98HPi ............. REU-KA3237FFUD-US
FOR OUTDOOR APPLICATIONS ONLY
RC80HPe ............ REU-KA2530WD-US
RC98HPe ............ REU-KA3237WD-US
Table of Contents .................... 2
Operating Instructions .............. 5
Maintenance ............................ 12
Error Codes ............................. 13
Consumer Support ................... 42
French Version ........................ 44

Publicité

Chapitres

Table des Matières
loading

Sommaire des Matières pour Rinnai RC80HPi

  • Page 1: Table Des Matières

    Direct Vent Tankless Water Heater Operation and Installation Manual FOR INDOOR APPLICATIONS ONLY RC80HPi ..... REU-KA2530FFUD-US RC98HPi ..... REU-KA3237FFUD-US FOR OUTDOOR APPLICATIONS ONLY RC80HPe .... REU-KA2530WD-US RC98HPe .... REU-KA3237WD-US Table of Contents ....2 Consumer Safety Information .. 4 Operating Instructions ....5 Maintenance ......
  • Page 2 Limited Warranty ........42, 43 General Instructions ........17 Clearances from Appliance ......18 French Version ..........44-62 Attachment of the Water Heater ....18 Electrical Connection ........19 Error Indication or Air Handler Control Switch19 Manual - Rinnai Condensing Water Heaters...
  • Page 3: Specifications

    * Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature. ** for commercial and hydronic applications requiring higher temperatures Rinnai is continually updating and improving products. Therefore, specifications are subject to change without prior notice.
  • Page 4: Consumer Safety Information

    • Power Failure: The appliance will cut off the gas if it loses electrical power. Manual - Rinnai Condensing Water Heaters...
  • Page 5: Operating Instructions

    Description of Operation The Rinnai water heater is one of the most advanced Ignition is electronic. There is no pilot light consuming water heaters available. It provides a continuous gas while the water heater is not being used. The gas supply of hot water at a preset temperature.
  • Page 6: Temperature Controllers - Models

    Display In Use Temperature Indicator Selection Priority ON/OFF Button Button * Requires the transceiver, MC-502RC- Refer to the MC-502RC-1US-S manual and the Wireless Controller Installation Instructions for complete details on features, operation, and installation. Manual - Rinnai Condensing Water Heaters...
  • Page 7 Clock Water Volume Temperature Sound Volume Selection MC-100V-1US Dimensions (inches): 5.0 W x 4.75 H x 0.75 D Temperature In Use Selection Indicator Function Temperature Display Priority Button and Indicator Clock ON/OFF Button Call Manual - Rinnai Condensing Water Heaters...
  • Page 8: How To Set The Temperature

    Rinnai water heater is schools, day care centers, and all ready to supply hot water. other public applications. If a newly installed unit with a...
  • Page 9: Temperature Options Without A Temperature Controller

    Water temperatures over 125º F (51º C) can cause severe burns or scalding. Refer to the Danger Alert on water temperatures. Rinnai shall not, in any event, be liable for damages resulting from such misuse or misapplication. A temperature lower than 98º F (37º C) can be Suggested temperatures are obtained at the tap by mixing with cold water.
  • Page 10: Using The Water Smart Bath Fill Function

    Be careful not to overfill the bath. An NOTICE controlling the temperature and average bath volume is 60 gallons. that the Rinnai water heater is When filling the bath using this ready to supply hot water. function for the first time: To Prevent 4.
  • Page 11: Filling The Tub

    Press the “Function” button twice within 10 seconds to set the clock. Press the ▲ or ▼ button to reach the desired time. The clock on the BC-100V automatically shows the time which has been set on the MC-100V. Manual - Rinnai Condensing Water Heaters...
  • Page 12: Maintenance

    If you receive Error Code “LC”, refer to the procedure, Flushing the Heat Exchanger. Refer to the section on Water Quality to see if your water needs to be treated or conditioned. (When checking maintenance code history, “00” is substituted for “LC”.) Manual - Rinnai Condensing Water Heaters...
  • Page 13: Error Codes

    Error Codes The Rinnai water heater has the ability to check its own operation continuously. If a fault occurs, an error code will flash on the Display of the temperature controller. This assists with diagnosing the fault and may enable you to overcome a problem without a service call.
  • Page 14 Ensure you have at least the minimum flow rate required to fire unit. Ensure turbine spins freely. Measure the resistance of the water flow control sensor. Check for DC shorts at components. Manual - Rinnai Condensing Water Heaters...
  • Page 15: Trouble Shooting For Common Issues

    I don’t have any hot water when I open the tap. water. Make sure there is gas, water, and electricity to the Rinnai water heater (power is turned on and the gas is Hot water must travel through your plumbing from the turned on).
  • Page 16: Flushing The Heat Exchanger

    Place filter back into unit and open (V4). 13. Restore electrical power to the water heater. Cleaning solution is 4 gallons of undiluted virgin, food grade, white vinegar. Circulating Pump Manual - Rinnai Condensing Water Heaters...
  • Page 17: Installation Instructions

    RC98HPi ..... REU-KA3237FFUD-US Rinnai highly recommends all installers attend a product knowledge class. FOR OUTDOOR APPLICATIONS ONLY For information on a Rinnai Training Course or for questions on installation call 1-800-621- RC80HPe .... REU-KA2530WD-US 9419. RC98HPe .... REU-KA3237WD-US General Instructions •...
  • Page 18: Clearances From Appliance

    Ensure that the attachment strength is wall installation sufficient to support the weight. Refer to the brackets weight of the water heater in the Specifications section. Manual - Rinnai Condensing Water Heaters...
  • Page 19: Electrical Connection

    National Electrical Code, ANSI/NFPA 70 and/or the CSA C22.1, Canadian Electrical Code. Error Indication or Air Handler Control Switch When using the Rinnai water heater with an Error Indication Switch, dip switch No. 4 in the bank of 8 switches should be in the off position. This is the default position.
  • Page 20: Pipe Sizing Procedure - Example

    Specific Gravity: 1.50 cubic feet per hour Capacity in Thousands of BTU per Hour Pipe Size (inches) Pipe Size (inches) Length Length 1 1/4 1 1/2 1 1/4 1060 1580 1150 2350 1090 1620 1300 1110 Manual - Rinnai Condensing Water Heaters...
  • Page 21: Water Piping General Instructions

    • Ensure that the water filter on the Rinnai water • Purge the water line to remove all debris and air. heater is clean and installed.
  • Page 22: Freeze Protection Piping

    2. Close the gas and water valves and turn off the power. 3. Wait until the water thaws. Check by opening the water supply valve. 4. Check the water heater and the piping for leaks. Manual - Rinnai Condensing Water Heaters...
  • Page 23: Recommended Piping For Basic Installation

    It is the responsibility of the contractor/engineer to ensure installation is in Check Valve Boiler Drain Valve accordance with all local building codes. Confer with local building Pressure Relief Valve officials before installation. Solenoid Valve Manual - Rinnai Condensing Water Heaters...
  • Page 24: Recommended Piping For Circulation Systems

    IMPORTANT: Connect the building Electric Water return line to the hot water supply line Heater as close as possible to the Rinnai Water Building Heater. Fixtures This is not an engineered drawing. It is intended only as a guide and not as a replacement for professionally engineered project drawings.
  • Page 25: Optional Piping For Circulation Systems

    Rinnai water Rinnai Equipment List heater, supply and return plumbing. Refer - ence the Rinnai Hot Water System Design Rinnai Water Heaters Manual, Pump Sizing for Circulation. Pump to be of bronze or stainless construc - RIK-KIT (Optional) tion.
  • Page 26: Venting Instructions Intake / Exhaust Guidelines

    Support horizontal vent runs every four feet and all If it becomes necessary to access an enclosed vent vertical vent runs every six feet or in accordance system for service or repairs, Rinnai is not responsible with local codes. for any costs or difficulties in accessing the vent •...
  • Page 27: Maximum Vent Length

    Vent Manufacturer Contact Information for Installation Instructions and Parts Lists: Rinnai/Ubbink Heat-Fab Metal-Fab Inc. Telephone: 800-621-9419 Telephone: 800-772-0739 Telephone: 800-835-2830 Fax: 678-829-1666 Fax: 413-863-4803 316-943-2351 Web Site: www.rinnai.us E-mail: custsvc@heat-fab.com Fax: 316-943-2717 Web Site: www.heatfab.com E-mail: info@mtlfab.com Web Site: www.metal-fabinc.com Manual - Rinnai Condensing Water Heaters...
  • Page 28: Flue Terminal Clearances

    For clearances not specified in ANSI Z223.1/NFPA 54 or CSA B149.1, clearances are in accordance with local installation codes and the requirements of the gas supplier. Clearance to opposite wall is 24 inches (60 cm) for Canada and US. Manual - Rinnai Condensing Water Heaters...
  • Page 29: Additional Clearances

    Additional Clearances - Vent Terminal (RC80HPi, RC98HPi) Local codes supersede these clearances. • Avoid termination locations near a dryer vent. • Avoid termination locations near commercial cooking exhaust. • For air intake position, follow the ANS Z21.10.3 ● CSA 4.3 requirements on the previous page.
  • Page 30 (0.91 m) to ventilated or unventilated soffit or eve vent; or 36" to a deck or porch 12" (0.30 m) to an inside corner 2" (50 mm) between Rinnai terminals at same level IN S ID E C O R N E R Manual - Rinnai Condensing Water Heaters...
  • Page 31: Flue Installation (Indoor Models)

    Slope the venting toward the appliance according to the vent manufacturers installation instructions. Dispose of condensate per local codes. Secure the first vent component to the water heater Securing with one self-tapping screw at the hole located above the condensate collector. Manual - Rinnai Condensing Water Heaters...
  • Page 32: Connecting Multiple Water Heaters

    No. 3 in the OFF position. 0-2000 ft 2001-5200 ft 5201-7700 ft 7701-10200 ft (0-610 m) (610-1585 m) (1585-2347 m) (2347-3109 m) Switch No. 2 Switch No. 3 Switch No. Switch No. Switch No. Switch No. Manual - Rinnai Condensing Water Heaters...
  • Page 33 Installation Codes / La conversion sera exécuté par un représentant du fabricant autorisé, conformément aux conditions du fabricant, les autorités provinciaux ou territoriaux ayant la juridiction et conformément aux con- ditions du CAN/CGA-B149.1 ou CAN/CGA-B149.2 Codes d'Installa- tion Manual - Rinnai Condensing Water Heaters...
  • Page 34: Temperature Controller Installation

    22 AWG. The maximum cable length from each 328 ft (100 m) controller to the water heater depends on the total number of wired controllers connected to the water 164 ft (50 m) heater. 3 or 4 65 ft (20 m) Manual - Rinnai Condensing Water Heaters...
  • Page 35: Mounting The Controller

    2. Outline of Remote 7. Disconnect the power from the Rinnai water heater. 8. Remove the cover of the Rinnai water heater. securing screw 9. Remove the plastic cover from the PC board 1-21/32" and electrical connections.
  • Page 36: Operating Instructions

    1. Turn off all electric power to the appliance using 3. Locate the manual gas valve on the side of the the ON/OFF button. heater. Turn the manual valve clockwise to the full OFF position. 2. Set the thermostat to lowest setting. Manual - Rinnai Condensing Water Heaters...
  • Page 37: Technical Data

    RC98HP Water Flow (gpm) The chart below only applies to incoming water temperatures of 70°F (21°C) or less. For NOTICE incoming water temperatures greater than 70°F (21°C) please contact Rinnai. Outlet Flow Data RC98HP RC80HP delta T - Temperature Rise (ºF)
  • Page 38: Space Heating

    Iron Components Do not use Rinnai water heaters directly for space heating applications involving iron radiators or applications with any iron components. Iron components may oxidize creating rust that will clog the inlet filter of the Rinnai water heater. Manual - Rinnai Condensing Water Heaters...
  • Page 39: Dimensions

    Condensate Drain - from 7.7 (195) 7.7 (195) 7.7 (195) 7.7 (195) center * This is the minimum dimension from the wall. The wall bracket is adjustable to allow an additional 1.57 inches (40 mm). Manual - Rinnai Condensing Water Heaters...
  • Page 40: Ladder Diagram

    Ladder Diagram TWIN THERMISTOR WATER WATER LEVEL LEVEL DETECTING ELECTRODE CIRCUIT Manual - Rinnai Condensing Water Heaters...
  • Page 41: State Regulations

    State Regulations NOTICE BEFORE INSTALLATION Rinnai direct-vent appliance must be installed by a state qualified or licensed contractor and a properly trained Rinnai Installer. If you are not properly trained, you must not install this unit. IMPORTANT: In the State of Massachusetts (248 CMR 4.00 & 5.00)
  • Page 42: Consumer Support

    (except when an MCC-91 is used with a Rinnai Hydronic Air Handler). The integrated controller on indoor models has a 1 year warranty on parts. † Note: Period of coverage is reduced to 3 years from date of purchase if the Rinnai water heater temperature setting exceeds 160º F (71º C).
  • Page 43 Replacement of the product may be authorized by Rinnai only. Rinnai does not authorize any person or company to assume for it any obligation or liability in connection with the replacement of the product. If Rinnai determines that repair of a product is not possible, Rinnai will replace the product with a comparable product at Rinnai’s discretion.
  • Page 44 • Si vous ne pouvez rejoindre le fournisseur, appelez le service des incendies. — L'installation et l'entretien doivent être assurés par un installateur ou un service d'entretien qualifié ou par le fournisseur de gaz. Manuel – Rinnai Condensing Water Heaters...
  • Page 45: Instructions D'utilisation

    Vérifiez vos normes locales concernant la AVIS indiquant que ce contrôleur est température maximale de l'eau permise contrôlant la température et la Rinnai pour une utilisation dans maisons de de l'eau poêle est prête à fournir de soins, écoles, garderies, et pour toutes l'eau chaude.
  • Page 46: Plages De Température Avec Un Contrôleur De Température

    125º F (51º le C) peut causer des brûlures ou scalding sévère. Se référer à l'Alerte de Danger sur les températures d'eau. Rinnai ne fait pas, en tout cas, être responsable des dommages qui résultent de tel usage impropre ou tel AVERTISSEMENT mauvais usage.
  • Page 47: Entretien

    (Lors de la vérification de l'historique des anomalies pour l'entretien, le code « 00 » aura remplacé « LC ».) Manuel – Rinnai Condensing Water Heaters...
  • Page 48: Instructions Générales

    • • Cet appareil ne convient pas pour une utilisation dans une Le RC80HPi (REU-KA2530FFUD-US) et RC98HPi (REU- application comme le chauffage d'eau de piscine ou de KA3237FFUD-US) ne doivent pas être installé à spa utilisant de l'eau chimiquement traitée (cet appareil l'extérieur.
  • Page 49: Écartements Par Rapport À L'appareil

    Assurez-vous que la résistance des fixations est suffisante pour supporter le poids de l'appareil. Reportez-vous au Supports poids des modèles de chauffe-eau dans la section des d'installation spécifications. murale Manuel – Rinnai Condensing Water Heaters...
  • Page 50: Installations À Haute Altitude

    Switch No. sera exécuté par un représentant du fabricant autorisé, conformément aux conditions du fabricant, les autorités provinciaux ou territoriaux ayant la juridiction et conformément aux con- ditions du CAN/CGA-B149.1 ou CAN/CGA-B149.2 Codes d'Installa- tion Manuel – Rinnai Condensing Water Heaters...
  • Page 51: Tuyauterie De Gaz

    être rincée avec de l'eau -eau Rinnai. Un raccord union peut être utilisé sur la après le test, sauf si vous avez pu déterminer que la connexion au-dessus de la vanne de coupure pour solution de détection utilisée n'était pas corrosive).
  • Page 52: Tuyauterie D'eau

    à eau potable. potable. • • Purgez la conduite d'eau pour en éliminer les débris et Le filtre d’eau du chauffage Rinnai dout être propre et l'air. Des débris entrant dans le chauffe-eau Rinnai installé. pourraient l'endommager. Soupape de sûreté...
  • Page 53: Tuyauterie Recommandée Pour Installation De Base

    Consultez les autorités compétentes dans Clapet anti-retour chaudière accordance with all local building codes. Confer with local building ce domaine avant l'installation. Pressure Relief Valve officials before installation. Solenoid Valve Soupape de décharge Électrovanne Manuel – Rinnai Condensing Water Heaters...
  • Page 54: Instructions De Ventilation Consignes Pour Aspiration/Évacuation

    La ventilation doit être aussi directe que possible avec un minimum de raccords de tuyauterie. S'il devient nécessaire d'accéder à un circuit de mise à l'air libre inclus pour le service ou les réparations, Rinnai n'est • Le diamètre de ventilation ne doit pas comporter de pas responsable d'aucuns coûts ou difficulté...
  • Page 55: Longueur De Ventilation Maximum

    N° 1 n'est pas en position correcte. Sur le R94LSi, la capacité maximale de débit d'eau sera réduite d'environ 10% quand ce microcommutateur N° 1 est en position OFF. Manuel – Rinnai Condensing Water Heaters...
  • Page 56: Produits De Ventilation

    Téléphone : 800-772-0739 Téléphone : 800-835-2830 Fax : 678-829-1666 Fax : 413-863-4803 316-943-2351 Site Web : www.rinnai.us Courriel : custsvc@heat-fab.com Fax : 316-943-2717 Site Web : www.heatfab.com Courriel : info@mtlfab.com Site Web : www.metal-fabinc.com Manuel – Rinnai Condensing Water Heaters...
  • Page 57: Espacement Pour Terminaison De Cheminée

    Pour les espacements non spécifiés dans ANSI Z223.1/NFPA 54 ou CSA B149.1, il faut appliquer les valeurs conformes aux normes locales d'installation et aux exigences du fournisseur de gaz.. L'espacement par rapport au mur opposé est de 24" (60 cm) pour Canada et USA. Manuel – Rinnai Condensing Water Heaters...
  • Page 58: Installation De Conduit De Cheminée

    Installation de conduit de cheminée (RC80HPi, RC98HPi) Horizontal Termination Inclinent n'importe quelle mise à l'air libre horizontale 1/4 pouce par pied (19 millimètres/m), vers le réchauffeur. Débarassez-vous du condensat par codes locaux. Vertical Termination Inclinent n'importe quelle mise à l'air libre horizontale 1/4 pouce par pied (19 millimètres/m), vers le...
  • Page 59: Instructions D'utilisation

    3.Repérez la vanne de gaz manuelle sur le côté du chauffe- son bouton M/A. eau. Fermez-la en la tournant à fond dans le sens horaire (position OFF). 2.Réglez le thermostat sur la consigne la plus basse. Manuel – Rinnai Condensing Water Heaters...
  • Page 60: Diagramme En Escalier

    SORTIE D'EAU 1 DISTANCE DISTANCE JUMEAU THERMISTANCE DE THERMISTOR SORTIE D'EAU 2 THERMISTANCE D'É- CHAGEUR THERMIQUE CIRCUIT DE THERMIS- NIVEAU D'EAU NIVEAU D'EAU TANCE THERMISTANCE DE DÉTECTANT LE DÉTECTANT LE BRÛLEUR CIRCUIT CIRCUIT MODÈLE D'INTÉRIEUR UNIQUEMENT Manuel – Rinnai Condensing Water Heaters...
  • Page 61: Informations Sur La Garantie

    L'utilisation d'un contrôleur MCC-91 dans une habitation résidentielle réduira la couverture de garantie au niveau de la garantie pour une application commerciale † Note : La période de garantie est réduite à 3 ans à partir de la date d'achat si le réglage de température du chauffe-eau Rinnai dépasse 160°F (71 °C).
  • Page 62: Garantie Limitée

    Rinnai le remplacera par un produit comparable, à sa discrétion. Si un composant ou un produit retourné à Rinnai est trouvé sans défaut du aux matériaux ou à la main d'œuvre, ou qu'il est déterminé qu'il a été...
  • Page 63 Notes Manual - Rinnai Condensing Water Heaters...
  • Page 64 • Available in Four Options of Fronts • Remotes and Fan Included • Gas Conversion Kit Available Hydronic Air Handler • Designed for Use with Rinnai Systems • Domestic Hot Water Priority • Optional Programmable Thermostat • Zero Clearance to Combustibles •...

Table des Matières