How to Set the Temperature
This water heater requires a minimum flow rate to operate. This rate can be found on the speci cati n page in
this manual. In some cases when you are not getti
it is due to the water flow being below or close to the minimum ow rate. Increasing the ow rate should
resolve these problems in these cases.
If you are experiencing issues with higher temperature setti s, then reduce the temperature se ng. Selecti g a
temperature closer to that which is actually used at the faucet will increase the amount of hot water being
delivered to the faucet, due to less cold water mixing at the xture.
DANGER
Adjus ng the Temperature
1.Ensure the controller is "ON" and that the Priority
icon is displayed.
2.Press the "UP" or "DOWN" bu ons as needed to set
the controller to the desired temperature.
-The temperature will increase by 2 degree
increments between 98-110 F. Once above 110 F
the temperature will change by 5 degree incre-
ments.
3.Proceed to open the tap to allow water to ow
through the unit allowing combus on to begin.
-During the call for hot water while the burners are
activ , the "Combusti n" icon will appear on the
screen.
Combusti n
Icon
60
hot water or if the water alternates between hot and cold,
Water temperatures over 125° F (52° C) can cause severe burns or scalding
resulti g in death.
Hot water can cause rst degree burns with exposure for as little as:
3 seconds at 140° F (60° C)
20 seconds at 130° F (54° C)
8 minutes at 120° F (49° C)
Children, disabled, or elderly are at highest risk of being scalded.
Feel water before bathing or showering.
NOTICE
NOTICE
NOTICE
NOTICE
Hot Water
Temperature
KBP Series Manual
While any hot water is being provided,
the temperature se ng can only be
adjusted between 98° F and 110° F.
Check local codes for the maximum water
temperature setti
allowed when used
in nursing homes, schools, day care
centers, and all other public applicati ns.
If power is interrupted and a newly
installed unit with a controller has not
been powered for at least 6 hours then
the temperature will return to the default
se ng of 104° F (40° C).
There may be a varia on between the
temperature displayed on the
temperature controller and the
temperature at the tap due to weather
condi ons or the length of pipe to the
water heater.