Adjustment for High Altit de
Set SW2 and SW3 in DIPSW 1 to the values shown in
table below for your altitude. The default se ng for
the appliance is 0-2000 ft (0-610 m) with switches
SW2 and SW3 in the OFF posi on.
When the DIP switch is adjusted, it is not necessary to
adjust the gas pressure setti
Altitu e
0-2000 ft (0-610 m)
2001-5200 ft (610-1585 m)
5201-7700 ft (1585-2347 m)
7701-10200 ft (2347-3109 m)
Adjustment for Vent Length
(indoor models only)
Adjust SW 1 in DIPSW 1 if required. Refer to the
section "Maximum vent length".
for high altitude.
SW 2 in
SW 3 in
DIPSW 1
DIPSW1
OFF
OFF
OFF
ON
ON
OFF
ON
ON
KBP Series Manual
Checklist for Gas and Electricity
A manual gas control valve is placed in the gas
line to the water heater.
Check the gas lines and connecti ns for leaks.
Con rm that the gas inlet pressure is within
limits.
Con rm that the water heater is rated for the gas
type supplied.
Con rm that the electricity is supplied from 120
VAC, 60 Hz power source and is in a properly
grounded circuit.
Con rm that an extension cord or an adapter plug
has NOT been used with the water heater.
49