Assembling the Pizza Oven
NEVER CONNECT A GAS LINE DIRECTLY TO THE PIZZA OVEN. A PRESSURE REGULATOR MUST BE
INSTALLED ON ALL GAS EQUIPMENT. REMOVING OR FAILING TO INSTALL THE PRESSURE REGULATOR
CAN RESULT IN FIRE, AND SERIOUS PERSONAL INJURY AND WILL VOID THE WARRANTY. THIS PIZZA OVEN
IS DESIGNED FOR NON-COMBUSTIBLE ENCLOSURES ONLY AND MUST BE INSTALLED AND SERVICED BY A
LICENSED INSTALLER TO LOCAL CODES.
AS INDICATED ON THE RATING PLATE, THIS GAS PIZZA OVEN IS DESIGNED TO OPERATE WITH GAS
SUPPLY PRESSURE OF 7" WC FOR NATURAL GAS. FOR INSTALLATIONS WHERE THE GAS SUPPLY PRESSURE
EXCEEDS THESE REQUIREMENTS, A REGULATOR MUST BE INSTALLED UPSTREAM OF THE PIZZA OVEN'S
COMPONENTS. IF THE GAS SUPPLY PRESSURE IS LOWER THAN THESE REQUIREMENTS, THE UNIT WILL BE
UNDER-FIRED AND WILL NOT REACH THE MAXIMUM TEMPERATURES. ENSURE THAT THE SUPPLY LINE
SIZE COMPLIES WITH LOCAL AND/OR NATIONAL INSTALLATION CODES.
The Pizza Oven is factory set to use natural gas (NG). It is critical that the gas you use matches that
which the Pizza Oven was set up for. You can verify that by checking the rating plate.
67980 - Outdoor Kitchen Platinum 33in Built-In Pizza Oven - Natural Gas
CLASS NO / CATÉGORIE #: C 2711 04/84
WARNING:
TURN OFF PROPANE GAS SUPPLY AT CYLINDER WHEN APPLIANCE IS
OUTDOOR KITCHEN PLATINUM 33"
NOT IN USE. IF THESE INSTRUCTIONS ARE NOT FOLLOWED EXACTLY, A FIRE CAUSING
BUILT IN PIZZA OVEN NATURAL GAS
DEATH OR SERIOUS INJURY MAY OCCUR.
OUTDOOR COOKING APPLIANCE- FOR OUTDOOR USE ONLY. IF STORED INDOORS,
DETACH AND LEAVE CYLINDER OUTDOORS. DO NOT USE THIS APPLIANCE UNDER
ATTENTION:
OVERHEAD COMBUSTABLE SURFACES.
ONLY FOR INSTALLATION IN A BUILT-IN
COUPER L'ALIMENTATION EN GAZ PROPANE À LA BOUTEILLE SI
ENCLOSURE CONSTRUCTED OF NON-COMBUSTIONABLE MATERIALS. /
APPAREIL DE
L'APPAREIL N'EST PAS UTILIS É . SI CES INSTRUCTIONS NE SONT PAS SUIVIES EXACTEMENT, UN
CUISINE DE PLEIN AIR- POUR UTILISATION À L'EXTÉRIEUR SEULEMENT. SI L'APPAREIL
INCENDIE CAUSE LA MORT OU DES BLESSURES GRAVES PEUVENT SURVENIR.
EST ENTREPOSÉ À L'INTÉRIEUR, ENLEVER LES BOUTEILLES ET LES LAISSER À
L'EXTÉRIEUR. NE PAS UTILISER CET APPAREIL SOUS UNE SURFACE COMBUSTIBLE.
CONVIENT UNIQUEMENT POUR INSTALLATION DANS UNE ENCEINTE ENCASTRÉE
FAITE DE MATÉRIAUX INCOMBUSTIBLES.
Rating Plate - Lists model numbers, and gas type
Water Column Requirements
Fuel
NATURAL GAS
The rating plate is located in one or more of the following places:
• On the back of the Pizza Oven
Ensure that the gas supplied meets with the minimum pressure requirements. Do not operate the
Pizza Oven on any gas other than that for which the Pizza Oven has been set.
Both the regulator and the manifold orifices have been tuned for the type of gas specified on the
rating plate.
All installation and all installation parts must conform to local codes with the National Electrical
Code, ANSI Z223.1/ NFPA 70 latest edition and the National Fuel Gas Code, ANSI Z223.1/NFPA 54 in
the U.S. and CGA-B149.1/.2 in Canada. Canadian installations must conform to CGA-B149.1/.2 natural
gas/propane installation code. (Canada)
22
WARNING
CAUTION:
MODEL / MODÈLE
THIS APPLIANCE IS ADJUSTED AND SHIPPED FOR USE WITH PROPANE GAS. USE ONLY THE
GAS PRESSURE REGULATOR SUPPLIED WITH THIS APPLIANCE. THIS REGULATOR IS SET FOR AN OUTLET
OUTDOOR KITCHEN PLATINUM
PRESSURE OF 11" in WC (2.739 kPa). IF THE GAS SUPPLY PRESSURE IS LOWER THAN THESE REQUIREMENTS, THE
33" BUILT IN PIZZA OVEN
UNIT WILL BE UNDER-FIRED AND WILL NOT REACH THE MAXIMUM TEMPERATURES. ENSURE THAT THE SUPPLY
NATURAL GAS
LINE SIZE COMPLIES WITH LOCAL AND/OR NATIONAL INSTALLATION CODES.
AVERTISSEMENT:
CET APPAREIL EST RÉGLÉ ET EXPÉDIÉ POUR UTILISATION AVEC DU GAZ
OUTDOOR KITCHEN PLATINUM 33IN
PROPANE. UTILISER UNIQUEMENT LE REGULATEUR DE PRESSION DE GAZ FOURNI AVEC CET APPAREIL. CE REGULATEUR
BUILT IN PIZZA OVEN NATURAL GAS
WITH CART
EST REGLE POUR UNE PRESSION DE SORTIE DE 11 POUCES DE COLONNE D"EAU (2.739 kPa). SI L'ALIMENTATION DE GAZ
LA PRESSION EST INFÉRIEURE À CES EXIGENCES, L'UNITÉ SERA SOUS-CUIT ET N'ATTAQUE PAS LES TEMPÉRATURES
EQUIPPED FOR USE WITH
MAXIMALES. ASSUREZ-VOUS QUE LA TAILLE DE LA LIGNE D'ALIMENTATION EST CONFORME AUX CODES
D'INSTALLATION NATIONAUX.
NATURAL GAS
WC Min Under Full load
7 in wc (NG)
1 X 18,000 BTUs BTU/ H MAIN BURNER / BRÛLEUR PRINCIPAL
MINIMUM CLEARENCE FROM SIDES AND BACK OF UNIT TO
COMBUSTIBLE CONSTRUCTION, 14 INCHES FROM SIDES, AND 18
1 X 22000 BTU/ REAR TUBE BURNER / BRÛLEUR À TUBE ARRIÈRE
INCHES FROM BACK. ONLY FOR INSTALLATION IN A BUILT-IN
ENCLOSURE CONSTRUCTED OF NON-COMBUSTIONABLE MATERIALS
67980
X
OR NEWAGE GRILL CABINETS. SEE MODELS.
DÉGAGEMENT MINIMAL ENTRE LES PAROIS LATÉRALES ET L'ARRIÈRE
ORIFICE SIZES/ GRANDEUR DES ORIFICS
PROPANE
DE L'APPAREIL ET LA CONSTRUCTION COMBUSTIBLE, 14 POUCES À
67120
PARTIR DES PAROIS LATÉRALES ET 18 POUCES À PARTIR DE
H - MAIN BURNER / BRÛLEUR PRINCIPAL - H
1.76MM
L'ARRIÈRE. UNIQUEMENT POUR L'INSTALLATION DANS UN BOÎTIER
REAR TUBE BURNER / BRÛLEUR À TUBE ARRIÈRE
1.96MM
INTÉGRÉ CONSTRUIT DE MATÉRIAUX NON COMBUSTIBLES OU POUR
APPAREIL DE GRILLE ET D'ARMOIRES NEWAGE.
PIZZA OVEN ELECTRICAL REQUIREMENTS:
111 CREDITVIEW ROAD, 2nd FLOOR
INPUT- 110 VAC 60 Hz 0.25A
L4L-9T1
MFG DATE DE FABRICATION :
Class IIIA-2
®
ANS Z21.58-2018•CSA 1.6-2018
Outdoor Cooking Gas Appliances