Installing Pizza Oven on custom built cabinet
The installation must conform with local codes or, in the absence of local codes, with the
National Fuel Gas Code, ANSI Z223.1/NFPA 54, Storage and Handling of Liquefied Petroleum
Gases, ANSI/NFPA 58; or Natural Gas and Propane Installation Code, CSA B149.1; Propane
Storage and Handling. If you are connecting an appliance to a fixed fuel piping system
specifying the use of a rigid pipe, semi-rigid tubing, and/ or a connector that complies
with the standard for Connectors for Outdoor Gas Appliances and Manufactured Homes,
ANSI Z21.75
CSA 6.27.
WARNING
Cabinet frame, cabinet side
panels and counter top must be
made from non-combustible
material.
Note to Installer :
All built-in appliances must use rigid pipe, semi-rigid tubing, or a connector complying with the
standard for Connectors for Gas Appliances, ANSI Z21.24. CSA 6.10, or Standard for Connectors for
Outdoor Gas Appliances and Manufactured homes, ANSI Z21.75. CSA 6.27, for the appliance which
are connected to fixed fuel piping system (Natural Gas).
THIS PIZZA OVEN IS DESIGNED FOR NON-COMBUSTIBLE ENCLOSURES ONLY, AND MUST BE
INSTALLED AND SERVICED BY A LICENSED GAS FITTER TO LOCAL CODES.
AS INDICATED ON THE RATING PLATE, THIS GAS PIZZA OVEN IS DESIGNED TO OPERATE WITH
SUPPLY PRESSURE OF 7" WC FOR NATURAL GAS. FOR INSTALLATIONS WHERE THE GAS SUPPLY
PRESSURE EXCEEDS THESE REQUIREMENTS, A REGULATOR MUST BE INSTALLED UPSTREAM
OF THE PIZZA OVEN'S COMPONENTS. IF THE GAS SUPPLY PRESSURE IS LOWER THAN THESE
REQUIREMENTS, THE UNIT WILL BE UNDER-FIRED AND WILL NOT REACH THE MAXIMUM
TEMPERATURES. ENSURE THAT THE SUPPLY LINE SIZE COMPLIES WITH LOCAL AND/ OR
NATIONAL INSTALLATION CODES.
CLEARANCES:
TO NON-COMBUSTIBLE CONSTRUCTION
A minimum of 4" (10 cm) clearance from the back of the Pizza Oven to non-combustible
construction is required to allow the hood to be opened fully.
TO COMBUSTIBLE CONSTRUCTION
This appliance should NOT be installed over, under or next to unprotected combustible
construction. A minimum clearance to vertical and rear combustible material is 18" (45 cm) and 14"
(36cm) on the sides.
The minimum vertical clearance to combustible materials means that ALL combustible materials
must be outside this 18" (45cm) zone. As an example, if you have an island with a stucco or tiled
surface and wood-frame construction beneath, the wood is considered combustible, even though
the Pizza Oven is touching the stucco or tile surface, which is non-combustible. In extreme
circumstances, the wood could potentially get hot enough to burn.
Do not store or use products with flammable
liquids or vapours in the vicinity of the NewAge
Cabinet, NewAge Outdoor Kitchen cabinets or any
appliances.
WARNING
WARNING
19