Installing Pizza Oven on custom built cabinet
Natural Gas Installation
Rigid Connection in a custom built cabinet
Only licensed gas fitter must perform the required gas fitting on NewAge gas appliances.
To ensure satisfactory performance, the gas supply line must be sized to accommodate the total
BTU/h requirements of all the gas-fired equipment that will be connected to that line. In no case
should pipe less than 3/4" inside diameter or 1" outside diameter ever be used to connect this
product.
Cutout Dimensions
SKU
33" Pizza
67980
Oven - Built-in
Natural Gas hose
(supplied)
Natural Gas
Supply
WARNING
W
D
31.5"
22.3"
11.2"
Natural gas Hose
(Supplied)
Natural Gas
Regulator
Natural gas Supply
Line
H
Securely mount the gas
supply components to the
non combustible
structure. This illustration is for
reference only each
installation will be different.
All Other Components are Not Supplied.
Non-combustible
construction
Rigid Piping for supply
(Not Supplied)
Quick Disconnect Coupling NG
(Not Supplied)
Flexible Gas Hose
Supply line
Ventilation
Gas line Flexible
corrugated Tubing
(Not Supplied)
21