Parametro
Valore
Min-On
Min-Off
Delay Btw Comps
Rotation Hours
RV Delay Time
RV Toggle On
RV Toggle Off
Supply High Temp
Differential
Supply Low Temp
Differential
Supply Return
Differential
Alarm Delay
Alarm Setup
High Pressure Sensor SP
Low Pressure Sensor
Heat Mode
Heat Mode
Alarm Delay
CW Flow Switch
Retrys
Set Disable
High Pressure Switch
Retrys
Low Pressure Switch
Retrys
Set Disable
CW Supply High Temp
Retrys
Set Disable
CW Supply Low Temp
Retrys
Set Disable
Low Pressure Sensor
Retrys
Set Disable
High Pressure Sensor
Retrys
Set Disable
Cond Freeze
Retrys
Set Disable
Configuration Menu
Temperature Units
Pressure Units
Tipo di dati
10
Seconds
10
Seconds
30
Seconds
1
Hour
5
Seconds
2
Seconds
2
Seconds
125
°F
20
°F
38
°F
4
°F
14
°F
120
Seconds
550
PSI
78
PSI
60
PSI
10
Seconds
3/30
1/min
20
Seconds
3/30
1/min
3/30
1/min
20
Seconds
3/0
1/min
20
Seconds
3/30
1/min
20
Seconds
3/30
1/min
20
Seconds
3/30
1/min
20
Seconds
3/30
1/min
180
Seconds
F
Degrees
PSI
7.5
Allarmi
Display
Ripristinare
Manuale
Chilled Water
Flow
Manuale
High Pressure
Limit
Manuale
Low Pressure Li-
mit
Manuale
High Temperature
Chilled Water
Manuale
Freeze Tempera-
ture (supply water)
Low Suction (pres-
Manuale
sure)
Manuale
High discharge
(pressure)
7.6
Mappe dei menu LCD
7.6.1
Navigazione nel menu
Menu A: On/Off Unit
• Unit Address: 1 (Default)
• Mode: Cool, Heat, EH, OFF
• Status: Displayed
Menu B: Setpoints
Cool Cntrl SP: 45 °F (7,22 °C)
• Stage Up Stage Down
• SP+ 1 °F >> 0 °F (17,78 °C)
• SP+ 3 °F >> – 2 °F (18,89 °C)
Heat Cntrl SP: 110 °F (43,33 °C)
• Stage Up Stage Down
• SP -1 °F >> 0 °F (17,78 °C)
• SP -3 °F >> 2 °F (16,67 °C)
Seawater Pump Control: By Demand (Default) or By Unit On (Continuous Operation)
Configurazione:
• Temperature Units: °F (predefinito) o °C
• Pressure Units: PSI (impostazione predefinita) o bar
Menu C: Clock/Scheduler
• Date: modificare la data qui.
• Hour: modificare l'ora qui.
• Day: Displayed
Schermata successiva:
• DST: Enabled (predefinito)
• Segue descrizione
Menu D: Input/Output
Visualizza i valori o lo stato di sensori analogici, ingressi digitali o uscite relè.
• A: Analog Inputs:
• CW Return
• Input B001: Actual Value
• Scorrere per altri valori del sensore con
• B: Digital Inputs:
• Flow Switch
• DI 3 Status: Actual State (Open or Closed)
Ritardo
Relè allarme
Azione
10 s
Relè del com-
pressore o del
riscaldamento
spento
Immediato
Compressore
spento
Immediato
Compressore
spento
Immediato
Relè del com-
pressore o del
riscaldamento
spento
Immediato
Compressore
spento
30 s
Segnale di av-
vertenza
30 s
Segnale di av-
vertenza
e quindi premere Esc per uscire.
    IT
75