– Central heating backup
– Start diff. ctrl. heat back. (ON temperature differential for
central heating backup)
– End diff. ctrl. heat. back. (OFF temperature differential for
central heating backup)
– Max. mixer temp. CH (Max. mixer temperature for central
heating backup)
– Mixer elapsed time CH (Mixer runtime for central heating
backup)
– Solar yield/optimisation
– Gross collector area 1
– Type collector array 1
– Gross collector area 2
– Type collector array 2
– Climate zone
– Min. DHW temp. (Minimum DHW temperature)
– Solar infl. heat. circ. 1 (Heating circuit solar 1...4)
– Reset solar yield
– Reset solar optimisation
– Set temp. Match-F. (Set temperature match-flow)
– Glycol content
– Transfer
– Transfer switch-on diff. (Transfer ON differential)
– Transfer switch-off diff. (Transfer OFF differential)
– Switch-on diff. diff. ctrllr (ON temperature differential,
differential controller)
– Switch-off diff. diff. ctrllr (OFF temperature differential,
differential controller)
– Max source t. diff ctrllr (Maximum source temperature,
differential controller)
– Min. src. temp. diff cont. (Minimum source temperature,
differential controller)
– Max. setbk temp. diff ctrl (Maximum sink temperature,
differential controller)
– Solar DHW
– DHW controller act. (Active DHW controller)
– Therm.dis./daily ht cyl1 (Thermal disinfection/daily heat-up
of cylinder 1)
– Therm.dis./daily ht cyl2 (Thermal disinfection/daily heat-up
of cylinder 2)
– Therm.dis./daily ht cyl3 (Thermal disinfection/daily heat-up
of cylinder 3)
1)
– Daily heat-up time
1)
– Daily heat-up temp.
– Start solar thermal system
2)
Transfer settings
– Change transfer configuration
– Current transfer configuration
– Transfer parameters
– Transfer switch-on diff. (Transfer ON temperature differential)
– Transfer switch-off diff. (Transfer OFF temperature differential)
– Max. DHW temp. (Maximum DHW temperature)
– Daily heat-up time (Daily heat-up time)
– Daily heat-up temp. (Daily heat-up temperature)
– Fault display
1) Only available if the module MS 200 is installed in a BUS system, without heat
production.
2) Only available if transfer system is on (code switch is on pos. 8)
MS 200 – 6721819173 (2020/02)
(Daily heat-up time)
(Daily heat-up temperature)
3)
DHW settings
– DHW system I
– DHW system I install. (DHW system I installed?)
– Config. DHW at boiler (DHW configuration at the heat source)
– Max. DHW temp. (Maximum DHW temperature)
– DHW
– DHW reduced
– Start temp. differential (ON temperature differential)
– Switch-off temp. diff.
– Flow temp. increase (Increase in flow temperature)
– DHW start delay (Power ON delay for DHW)
– Start cyl. primary pump
– DHW circ. pump installed (DHW circulation pump installed)
– DHW circulation pump
– DHW circ.pmp op. mode (Operating mode of DHW circulation
pump)
– Start frequency DHW circ. (DHW circulation pump start-up
frequency)
– Thermal disinfection
– Therm. disinfection temp.
– Therm. disinfection day (Day for the thermal disinfection)
– Therm. disinfection time (Time of thermal disinfection)
– Daily heat-up (Daily heat-up)
– Daily heat-up time (Time of daily heat-up)
Diagnosis
– Function test
– Activate function tests
– ...
– Solar
– ...
– ...
– Monitored values
– ...
– Solar
– ...
– Fault displays
– ...
– System information
– ...
– Maintenance
– ...
– Reset
– ...
– Calibration
– ...
3) Only available if primary store system is on (code switch is on pos. 7)
Commissioning
35