Installation
3.2.4
Overview of terminal assignment
Using examples, this overview indicates which system parts can be
connected for all terminals in the module. The components (such as VS1
and VS3) identified with * in the system, are possible alternatives.
Depending on how the module is used, one of the components is
connected to the "VS1/PS2/PS3" terminal.
VS1,
PS2, PS3
N 74 75
N 74 75
N 74 75
4
74 75
N
N
M
M
VS3*
N L
N L
M
M
PS5
VS2
Legend to the above figure and connection diagrams can be found at
the end of this document (no designation assigned to terminals
Table 5 for these designations):
Solar thermal system
Function
Additional function in the solar system (shown in grey)
Transfer or primary store system 3/4
Transfer or primary store system 5
Transfer or primary store function
Additional function in the transfer or primary store system
(shown in grey)
Earth wire
Temperature/temperature sensor
BUS connection between heat source and module
No BUS connection between heat source and module
[1]
1st cylinder (transfer system 3: stratification cylinder)
[2]
2nd cylinder (transfer system 3: buffer cylinder)
[3]
3rd cylinder (transfer system 3: standby cylinder)
230 V AC Mains voltage connection
BUS
BUS system
M1
Pump or valve controlled via temperature differential controller
PS1**
Solar pump, 1st collector array
PS3**
Cylinder primary pump for cylinder 2 with pump
(solar thermal system)
PS4
Solar pump, 2st collector array
PS5
Cylinder primary pump when using an external heat exchanger
PS6
Cylinder primary pump for transfer system (solar thermal
system) without heat exchanger (and thermal disinfection)
PS7
Cylinder primary pump for transfer system (solar thermal
system) with heat exchanger
PS9
Thermal disinfection pump
PS10
Pump for active collector cooling
PS11
Pump on the heat source side (primary side)
PS12
Pump on the consumer side (secondary side)
PS13
DHW circulation pump
MS 100
Module for standard solar systems
MS 200
Module for advanced solar systems
32
120/230 V AC
PS5
VS2
N
63
N 43
44
120/230 V AC
VS1/PS2/PS3
120/230VAC 120/230VAC
N L
N
L
N 74
75
N L
N L
M
M
PS3
230 V AC 230 V AC
VS1*
More complex solar systems can be realised in combination with a
second solar module. Terminal assignments, which deviate from the
terminal overview, are possible with this option ( connection diagrams
with system schematics).
MS 200
24 V
TS6
TS7
TS8
IS2
PS4
TS4 TS5
N 63
1 2 1 2
1 2
1 2
1 2
1 2 3 4 1
24 V
PS1
TS1 TS2
TS3
IS1
OS1
N 63
1 2 1 2
1 2
1 2 3 4 1
2 3
N L
1 2 3
PWM
M
0-10V
PS1
TS1 TS2 TS3
TS13
PS1**
V
WM1
TS1
Temperature sensor for collector array 1
TS2
Temperature sensor at bottom of cylinder 1 (solar thermal
system)
TS3
Temperature sensor at middle of cylinder 1
(solar thermal system)
TS4
Temperature sensor for heating return to the cylinder
TS5
Temperature sensor at bottom of cylinder 2 or swimming pool
(solar thermal system)
TS6
Heat exchanger temperature sensor
TS7
Temperature sensor for collector array 2
TS8
Temperature sensor for heating return from the cylinder
TS9
Temperature sensor at top of cylinder 3, only connect to
MS 200 if the module is installed in a BUS system without a
heat source
TS10
Temperature sensor at top of cylinder 1 (solar thermal system)
TS11
Temperature sensor at bottom of cylinder 3 (solar thermal
system)
TS12
Temperature sensor in solar collector flow (heat meter)
TS13
Temperature sensor in solar collector return (heat meter)
TS14
Heat source temperature sensor
(temperature differential controller)
TS15
Heat sink temperature sensor
(temperature differential controller)
TS16
Temperature sensor at bottom of cylinder 3 or swimming pool
(solar thermal system)
TS17
Temperature sensor at heat exchanger
TS18
Temperature sensor at bottom of cylinder 1
(transfer/primary store system)
TS19
Temperature sensor at middle of cylinder 1
(transfer/primary store system)
TS20
Temperature sensor at top of cylinder 2 (transfer system)
VS1
3-way valve for central heating backup (
VS2
3-way valve for cylinder 2 (solar thermal system) with valve
VS3
3-way mixer for return temperature control (
VS4
3-way valve for cylinder 3 (solar thermal system) with valve
WM1
Water meter
**) Terminal assignment: 1 - earth; 2 - PWM/0-10V output; 3 - PWM input
OS2
2 3
BUS
BUS
1 2
1 2
BUS BUS
TS4 TS5 TS6
TS7
TS8
MS 200 – 6721819173 (2020/02)
**
PWM:
1-2
0-10V:
1-3
1 2 3
PWM
0-10V
TS12 PS3**
0010017304-002
)
)