6. Loosen the screws for the eye-guard. Remove the eye-
guard from the front adjusting ring.
7. Check the O-rings for any signs of damage and replace as
necessary.
8. Attach a new eye-guard to the front adjusting ring.
9. Tighten the screws of the eye-guard (torque: 2 Nm (1.48
lb-ft)).
10. Place the front adjusting ring in the helmet shell.
11. Press the function plate onto the helmet shell and place
the face-guard on the dome of the function plate between
the helmet shell and the front adjusting ring.
Instructions for use
|
Dräger HPS SafeGuard
12. Tighten the screws on the front adjusting ring (torque: 2
Nm (1.48 lb-ft)).
5.2.4 Replacing the internal helmet components
The internal helmet components include:
– Clip bracket
– Strap mount
– Harness
– Crown straps
– Rear head padding
– Front support ring with head padding
– Rear support ring
– Front adjusting ring
– Rear adjusting ring
– Cushioning element
Tools required:
– Torx screwdriver T15
– Torque screwdriver T15
– Installation cushion
Spare parts required:
– Spare part kit HPS SafeGuard rear adjusting ring, NFPA
(3724538) or clip bracket (3724501)
– Strap mount (3724501)
– Harness (3701665)
– Crown straps (3724529)
– HPS SafeGuard shock absorption pad NFPA (3724547)
– rear head padding (3701614)
– HPS SafeGuard front support ring basic NFPA (3724544)
– Rear support ring (3724578)
– HPS SafeGuard front adjusting ring NFPA (3724546)
– HPS SafeGuard rear adjusting ring NFPA (3724540)
– Cushioning element (3724513)
|