Design Guide - Single Standard Installation
SINGLE STANDARD INSTALLATION SPACE
Dimensions in parentheses are in centimeters.
35-1/2" (90.2)
*83 1/2" min.
*84 1/2" max.
(212.1 – 214.6)
*Trim will overlap
9"
additional 3/4"
18"
(22.9)
(45.7)
8"
9"
(20.3)
(22.9)
ELECTRIC
WATER
For 24" Deep Cutouts
A trim kit (ZKW36V) is required for standard
installations.
Water And Electrical Locations
The recommended electrical location is shown in
the diagram. If the electrical location is higher than
shown, use the longer power cord provided in trim kit
(ZKW36V). Follow instructions in step 4 to change
power cord.
Water supply must be located as shown.
Product Clearances
These units are equipped with a 2-position door stop.
The factory set 115° door swing can be adjusted to 90°
if clearance to adjacent cabinets or walls is restricted.
Refer to Dim A on page 6 for clearances needed for
door swing.
Additional Specifications
• A separate 115 volt 60Hz., 15 or 20 amp power
supply is recommended for each product. An
individual properly grounded branch circuit or circuit
breaker is recommended. Install a properly grounded
3-prong electrical receptacle recessed into the back
wall. Electrical must be located on rear wall as shown.
• Water line must be located on the back wall as
shown. The water line should be 1/4" O.D. copper
tubing or QuickConnect
the cold water line and water connection location,
long enough to extend to the front of the unit (8'
[2.4m]). Installation of an easily accessible shut-off
valve in the water line is required.
31-1000708 Rev. 4
24" (61)
6"
(15.2)
Finished
Return on
both sides
and top
6" (15.2)
2 1/2" (6.4)
kit (WX08X10006) between
B
1-1/2" Landing / Finished Spacer
B
Cabinet
Hinge
Minimum Clearance Dimensions with Trims
Installed
• 3/4" Landing needed for cabinetry door/drawer edge
adjacent with hinge opposite of cutout.
• 1-1/2" landing needed for cabinetry door/drawer edge
with hinge adjacent to cutout
Trim
A
0.75 min
Hinge Opposite
Cutout.
A. Option clearance
Cabinet Handle next to trim. 3/4" Minimum landing
clearance (Matching Cabinet Finish) needed from
cutout opening for Standard Trim.
B. Option clearance
Cabinet hinge next to trim. 1-1/2" Minimum landing
clearance (Matching Cabinet Finish) needed from
cutout opening for Standard Trim to clear cabinetry
door hinges.
9
A
¾" Landing/Finished Space
A
Cabinet
Handle
B
1.5 min
Hinge Adjacent
to Cutout.