Installation Instructions - Single Standard Installation
STEP 5 CASE TRIM INSTALLATION
(Cont.)
Loosen the top cover hex head screws so that the
slots in the top trim can slide between the hex head
screws and the top cover.
Fit the top trim and side trim rails together by sliding
the exposed edges of the corner trim into the right
and left trim kit side rails.
Align and drive the two
number
8-32
Phillips head
screws into the screw
holes in the side rails
to ensure the top trim is
snugly fit to the side rails.
Tighten the top cover hex
head screws so that the
top trim is secured to the
cabinet.
STEP 6 CONNECTING WATER
SUPPLY
WARNING
Connect to potable water supply
only. A cold water supply is required for automatic
icemaker operation. The water pressure must be
between 40 and 120 psi (275-827 kilopascals).
AVERTISSEMENT
une alimentation d'eau potable seulement. Une
alimentation d'eau froide est requise pour faire
fonctionner la machine à glaçons et le pichet à
remplissage automatique. La pression d'eau doit se
situer entre 40 et 120 psi. (275 à 827 kPa).
ADVERTENCIA
suministro de agua potable únicamente. Se requiere
un suministro de agua fría para el funcionamiento
de la máquina de hielos automática y de la jarra de
llenado automático. La presión del agua deberá estar
entre 40 y 120 p.s.i. (275 – 827 kPa).
WARNING
ELECTRIC SHOCK HAZARD
Attach tubing clamp using existing hole only. DO
NOT drill into the refrigerator.
Raccordez l'appareil à
Realice la conexión a un
STEP 6 CONNECTING WATER
SUPPLY (Cont.)
AVERTISSEMENT
Fixez le collier de serrage dans le trou présent seulement.
NE PERCEZ PAS dans le réfrigérateur.
ADVERTENCIA
Adhiera la abrazadera de la tubería usando el agujero
existente únicamente. NO perfore el refrigerador.
House
Water Supply
Locate and bring the tubing to the front of the cabinet.
Turn the water on to flush debris from the line. Run
about a quart of water through the tubing into a
bucket, then shut off the water.
Remove strain relief screw to allow for enough slack
to make a proper water connection.
replaced in the next step.)
Strain Relief
Screw
Copper Tubing:
Slip a 1/4" nut and ferrule over both ends of the
copper tubing. Insert the tube into the union fitting on
the unit and tighten the nut to the union.
Turn on the water to check for leaks.
™
SmartConnect
Tubing:
NOTE: The only Monogram-approved plastic tubing is
supplied in the SmartConnect
Do not use any other plastic water supply line because
the line is under pressure at all times. Other types of
plastic may crack or rupture with age and cause water
damage to your home.
Insert the molded end of the tubing into the
refrigerator or freezer connection. Tighten the
compression nut until it is just hand-tight.
Follow the instructions provided with the tubing.
Overtightening can cause leaks!
Turn on the water to check for leaks.
14
RISQUE DE DÉCHARGE
ÉLECTRIQUE
PELIGRO DE DESCARGA
ELÉCTRICA
Refrigerator/
Freezer
Freezer
Water Supply
Water Supply
(Screw must be
™
Refrigerator Tubing kits.
31-1000708 Rev. 4