Design Guide - Dual Standard Installation
DUAL STANDARD INSTALLATION SPACE
Dimensions in parentheses are in centimeters.
*83 1/2" min.
*84 1/2" max.
(212.1-214.6 cm)
*Trim will overlap
additional 3/4"
B
1-1/2" Landing / Finished Spacer
Minimum Clearance Dimensions with Trims Installed
• 3/4" Landing needed for cabinetry door/drawer edge adja-
cent with hinge opposite of cutout.
• 1-1/2" landing needed for cabinetry door/drawer edge with
hinge adjacent to cutout.
A. Option clearance
Cabinet Handle next to trim. 3/4" Minimum landing
clearance (Matching Cabinet Finish) needed from cutout
opening for Standard Trim.
B. Option clearance
Cabinet hinge next to trim. 1-1/2" Minimum landing
clearance (Matching Cabinet Finish) needed from cutout
opening for Standard Trim to clear cabinetry door hinges.
31-1000708 Rev. 4
71 1/2" (181.6 cm)
54"
(137.2 cm)
44"
(111.8 cm)
9"
18"
(22.9 cm)
(45.7 cm)
8"
9"
(20.3 cm)
(22.9 cm)
ELECTRIC
WATER
B
Cabinet
Hinge
6" (15.2 cm)
Return on both
sides and top
9"
(22.9 cm)
9"
(22.9 cm)
ELECTRIC
WATER
6" (15.2 cm)
Trim
0.75 min
Hinge Opposite
Cutout.
31
24" (61 cm)
Finished
2 1/2"
(6.4 cm)
A
¾" Landing/Finished Spacer
A
Cabinet
Handle
A
B
1.5 min
Hinge Adjacent
to Cutout.