2. SAFETY INFORMATION
2.1. USING THIS MANUAL
The latest version of the unit's user manual can be downloaded
The latest version of the unit's user manual can be downloaded
by customers from our website (www.salicru.com)
by customers from our website
read carefully before carrying out any action, procedure or opera-
read carefully before carrying out any action, procedure or opera-
tion on the unit.
tion on the unit.
The purpose of the
SLC.CUBE4
mation relating to safety, as well as explanations about the unit's
installation and operating procedures. The generic documentation
for the unit is supplied in digital format on a pen drive and includes,
among other documents, the system user manual itself. .
Document EK266*08 relating to the
is supplied with the unit. Compliance
datory, with the user being legally responsible
vance and application.
All units are supplied with the corresponding labels to guarantee
the correct identification of each part. In addition, the user can
refer to the user manual at any time during installation or start-up
operation, which provides clear, well-organised and easy-to-under-
stand information.
Nevertheless and as the product is continuously being de-
veloped, there may be slight discrepancies or inconsisten-
cies. Therefore, in the case of any queries, the labels on the unit
itself will always take precedence.
Once the unit is installed and in operation, we recommend that you
keep all of the documentation in a safe place, in case of any future
queries that may arise.
This user manual is intended for
between 7.5 and 20 kVA, consisting of tower cabinets measuring
(depth x width x height) 688.5 x 250 (370
rack modules of (depth x width x height) 684 x 483 x 174 mm. (4U).
Dimensions corresponding to the unit with the stabi-
(1)
lising supports installed. For safety purposes, it is recom-
mended to install them to give the unit greater stability, largely
avoiding the risk of tipping (see Fig. 1).
The following terms are used interchangeably in the document to
refer to:
"SLC CUBE4, CUBE4, UPS, system, rack unit, equipment
•
or
unit".- Uninterruptible power supply, CUBE4 series.
Depending on the context of the sentence, they may refer in-
terchangeably to the UPS itself or to the UPS and the batteries,
regardless of whether it is assembled in the same metal enclo-
sure -box- or not.
"Batteries or capacitor
•
that stores the flow of electrons by electrochemical means.
"T.S.S.".- Technical Service and Support.
•
USER MANUAL
(www.salicru.com). It must be
. It must be
documentation is to provide infor-
"Safety instructions"
with these is man-
for their obser-
SLC CUBE4
series equipment,
) x 826.5 mm., and by
(1)
banks".- A group or set of elements
"Customer, installer, operator or
•
terchangeably and, by extension, to refer to the installer and/
or the operator who will carry out the corresponding actions,
whereby the responsibility for carrying out the respective ac-
tions may be held by the same person when they act on behalf
or in representation of the installer or operator.
2.1.1. Conventions and symbols
Some symbols may be used and may appear on the unit, batteries
and/or in the user manual.
For more information, see section 1.1.1 of document EK266*08 re-
lating to the
"Safety
Instructions".
When there are differences in relation to the safety instructions
between document EK266*08 and the unit's user manual, those
from the latter will always prevail.
2.1.2. Safety considerations
Although chapter will cover safety-related considerations in
•
more detail, the following will be taken into account:
Inside the battery cabinet there are accessible parts
with DANGEROUS VOLTAGES and consequently with
a risk of electric shock, which is why it is classified as a
RESTRICTED ACCESS AREA. Therefore the key for the
battery cabinet will not be available to the OPERATOR or
USER, unless they have been properly instructed.
In the event of an intervention inside the battery cabinet,
either during the connection, preventive maintenance or
repair procedure, it must be taken into account that
battery group voltage exceeds 200 V DC
fore the relevant safety measures must be taken.
Any connection and disconnection operation of the cables
or handling inside the cabinet must not be carried out until
10 minutes have passed, in order to allow the internal dis-
charge of the unit's capacitors. Even so, use a multimeter
to check that the terminal voltage is less than 36 V.
In case of installing the equipment in IT neutral regime,
the switches, circuit breakers and thermal-magnetic pro-
tection devices must break the NEUTRAL, as well as the
three phases.
SLC CUBE4 7,5 kVA a 20 kVA - UNINTERRUPTIBLE POWER SOIRCE (UPS)-
user".- They are used in-
the
and there-
79