10. Troubleshooting
Mechanical faults on pumps
Fault
Lubricant volume on one or more lubrication
points deviates from projected values
Pump is permanently on/
Pump does not switch off
Possible cause/ recognizability of fault
○ Wrong setting of pause time or number of me-
tering device cycles
○ Wrong cross-porting of outlets on the SSV me-
tering device
○ Indicator pin on metering device does not move
within switching distance of proximity switch or
indicator pin is not positioned centrically in front
of proximity switch
If the fault cannot be determined and remedied, please contact our Customer Service.
Remedy
○ Check and, if necessary, correct
pause time settings and metering device cycles
○ Check and, if necessary, correct
cross-porting of outlets
○ Check position and distance of indicator pin
(distance < 0.5 mm) and correct, if necessary
EN
10
45