4.3 Factory settings of pumps
Programming step/ value
P1 Pause time in hours
P2 Pause time in minutes
P3 Metering device cycles per operating cycle
P4 Signal output fault relay
P5 Differentiation of low-level signal and fault signal
P6 Start stage
Maximum runtime
Maxmum adjustable pause time = 59 hours 59 minutes
Minimum adjustable pause time V DC pump = 4 minutes
Minimum adjustable pause time V AC pump = 20 minutes
#
For the AC versions adhere to the following value in order to avoid pump failure due to exceeding the max. runtime:
mximum of 3 cycles
30
Factory setting
Setting range
6 hours
0-59 hours
0 minutes
0-59 minutes
V DC pumps 1-5 cycles
1 cycle
V AC pumps 1-3 cycles
no
NO contact / NC contact
-- (no differentiation)
-Π (output signal as no contact)
--
-U (output signal as nc contact)
[SP] Pump starts with pause time
SP
[SO] Pump starts with lubrication time
30 minutes
not modifiable
4. Technical data
#