Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 507
EN
4. Technical data

4.1 General technical data

Pump variant
Admissible operating temperature
Operating pressure
Installation position
Lubrication points
sound pressure level
Reservoir size
Filling
Weight of empty pump
Lubricants
2)
Output of pump element
2
Output of metering device
Maximum pump run time
1)
NLGI III lubricants may be supplied under certain operating conditions only. Therefore the lubricant's supply characteristics
has to be clariefied with SKF in advance.
2)
Observe the references given in chapter 4.6 and 4.7.
Temperature [°C]:
024 V DC
Speed [rpm]
120 V AC
Speed [rpm]
230 V AC
Speed [rpm]
The indicated rotational speeds depend on counterpressure and temperature. In principle the following applies:
The higher the counterpressure and the lower the temperature, the lower is the rotational speed.
28
-25 °C
-20 °C
5.3 - 6.0
6.2 - 7.3
5.9-6,9
8.3
2.5 - 5, 6
6.5 - 6.8
24 V DC
-25 °C to 70 °C
120 bar max.
vertical (max. deviation± 5 °)
max. 18
< 70 dB (A)
1 litre
via hydraulic lubrication fitting R 1/4
approx. 6 kg
Lubricating greases NLGI II and NLGI III
approx. 0.2 ccm (per stroke)
approx. 0.2 ccm (per cycle)
30 minutes
+25 °C
7.3 - 8.3
8.5 - 9.0
6.9 - 7.1
4. Technical data
120 V AC 60 Hz
230 V AC 50 Hz
1)
approx. 1.0 ccm (per minute)

Publicité

Table des Matières
loading

Table des Matières