SKF TLMP 1008 Serie Mode D'emploi page 307

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 507
EN
End of programming
Programming has been completed. To adopt the
values set the programming has to be confirmed
On
with the green key 3.3 (see Fig. 13) within 30
min
h
seconds.
Normally closed contact
Output signal is preset as normally closed con-
tact. Programming step P4
On
min
h
Normally open contact
Output signal is preset as normally open contact.
Programming step P4
On
min
h
Fault - low-level signal
No differentiation between fault and low-level
signal. Programming step P5
On
min
h
Output signal programmed as normally open
contact
Intermittent low-level signal, functional faults as
On
permanent signal (ON). Programming step P5
min
h
Output signal programmed as normally closed
contact
Intermittent low-level signal, functional faults as
On
permanent signal (OFF). Programming step P5
min
h
26
3. Overview, functional description
Start stage SP
When being switched on the pump starts with a
pause time. Programming step P6
On
min
h
Start stage SO
When being switched on the pump starts with
the lubrication time. Programming step P6
On
min
h
Remaining pause time
Consists of 3 consecutive displays that change in
a two second interval.
On
Display 1
min
h
Display 2
Shows the remaining pause time in hours.
On
min
h
Display 3
Shows the remaining pause time in minutes.
On
min
h
Example: 0110. Remaining pause time
1 hour and 10 minutes.