○ All components used must be designed
for:
- maximum operating pressure
- maximum / minimum ambient
temperature
- the lubricant to be supplied
- the ATEX zone required
- the operating / ambient conditions at
the place of usage.
○ No parts of the centralized lubrication
system may be subjected to torsion,
shear, or bending.
○ Check all parts prior to their usage for
contamination and clean, if necessary.
○ Lubricant lines should be primed with
lubricant prior to installation. This makes
the subsequent ventilation of the system
easier.
○ Observe the specified tightening torques.
When tightening, use a calibrated torque
wrench.
○ When working with heavy parts use sui-
table lifting tools.
○ Avoid mixing up or wrong assembly
of dismantled parts. Mark these parts
accordingly.
14
1.17 Initial commissioning, daily start-up
Ensure that:
○ All safety devices are completely available
and functional
○ All connections are correctly connected
○ All parts are correctly installed
○ All warning labels on the product are
present completely, highly visible and
undamaged
○ Illegible or missing warning labels are to
be replaced without delay
1. Safety instructions
1.18 Cleaning
○ Risk of fire and explosion when using
inflammable cleaning agents. Only use
non-flammable cleaning agents suitable
for the purpose.
○ Do not use aggressive cleaning agents.
○ Thoroughly remove residues of cleaning
agents from the product.
○ Do not use steam jet and high pressure
cleaners. Electrical components may be
damaged. Observe the IP type of protec-
tion of the pump.
○ Cleaning work may not be carried out on
energized components.
○ Mark damp areas accordingly.