4. Technical data
4.2 Electrics
Pump variant
Power supply with square plug (left side)
Tolerance of input voltage
Current input (maximum)
Types of protection
Inputs
Fault signals with square plug (right side)
Protective and disconnecting device required for isolation
Switching voltage
IP protection class of bayonet plug
AC fault relay for low level signal and fault signals
maximum switched current
DC fault relay for low level signal and fault signals
maximum switched current
Residual ripple (DIN 41755)
#
IP 67 only for square plugs with prefabricated cable
24 V DC
120 V AC
60 Hz
yes
yes
-20 / + 30 %
±10 %
≤ 1 A
≤ 1 A
PELV
protected against reverse polarity, short circuit proof, non-isolated
yes
yes
yes
yes
48 V AC / DC
48 V AC / DC
65
65
230 V AC
230 V AC
5 A
5 A
24 V DC
24 V DC
5 A
5 A
±5 %
±5 %
EN
230 V AC
50 Hz
yes
4
±10 %
≤ 0.5 A
yes
yes
48 V AC / DC
65
230 V AC
5 A
24 V DC
5 A
±5 %