Useable Reservoir Volume - SKF TLMP 1008 Serie Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 507
EN

4.6 Useable reservoir volume

The useable reservoir volume mainly depends on the NGLI consistency class and the operating temperature of the lubricant to be used.
In case of high consistency and low operating temperature normally more lubricant sticks to the inner surfaces of the reservoir/ pump and is thus no more
available for being dispensed.
Lubricants with relatively high consistency
Lubricants with relatively low consistency
4)
Lubricant consistencies of NLGI 2 lubricants at + 20 °C up to the maximum admissible lubricant consistency.
5
) Lubricant consistencies of NLGI-000 lubricants at + 70 °C up to lubricant consistencies of NLGI-1.5 lubricants at + 20 °C.
4.7 Lubricant requirement for priming of an empty pump
To prime an empty pump up to the MAX marking of the reservoir, the following lubricant quantities are required.
Reservoir size
Quantity
1 litre
1.75 litres ± 0.15
32
Useable reservoir volume
1-litre reservoir with low level indication (XL)
4)
approx. 0.5 to 0.8 litres
5)
approx. 0.6 to 0.9 litres
When using lubricants of a relatively low consistency in pumps subjected to srong vibrations or tilting
motions (e.g. construction and agricultural machinery), make sure to maintain a level that is about
25 mm below the MAX marking of the reservoir. This prevents lubricant from entering the reservoir
vent. In case of very strong vibrations this value must be increased, for low vibrations it can be reduced.
Changing the filling level by 10 mm corresponds to a volume change of about 0.2 litres.