Operating Instructions
Display mode
<up/info>
Brief press:
No function
Long press:
Displays the set parameters
• SP1/FH1
• RP1/FL1
• SP2/FH2 (if available)
• RP2/FL2 (if available)
• Analog output (if available)
• LOW
• HIGH
<down/menu>
Brief press:
No function
Long press:
Switches to programming mode.
A password prompt appears if a password is set
(≠ 0000). If the correct password is entered, the
device switches to programming mode; otherwise,
it reverts back to display mode.
<enter>
Brief press:
No function
Long press (> 200 ms)  starts the leakage
measurement (if this function is available –
only with PAC50-FGG) or  sets the LT back
to measurement standby (acknowledges the
measurement)
During the measurement, the measurement
can be canceled by a long press (> 2 seconds).
8017612/14NK / 8/2/2019 | PAC50
Subject to change without notice
Product description
Programming mode
Brief press:
• Moves menu up
• Increases/moves parameter value up
Long press:
• Moves menu up
• Increases/moves parameter value up
Brief press:
• Moves menu down
• Decreases/moves parameter value down
Long press:
• Moves menu down
• Decreases/moves parameter value down
Brief press:
• Selects menu entry
• Confirms the set parameter value
O p e r a t i n g I n s t r u c t i o n s | S I C K
PAC50
6 9