Operating Instructions
Analog output signal
Display
Table 9: Features
9.2 Performance
Non-linearity
Accuracy
Non-repeatability
Rated temperature range
Table 10: Performance
Underside: G ¼ female thread, rear: G ¼ female thread, both in acc. with DIN ISO 16030
1)
Underside: push-in fitting for 4 mm pneumatic hose, rear: G ¼ female thread in acc. with DIN ISO 16030
2)
For the voltage supply, use an energy-limited circuit as per UL61010-1 3rd Ed., Section 9.4
3)
1 0 4
O p e r a t i n g I n s t r u c t i o n s | S I C K
Technical data
Optional, 4 mA ... 20 mA / 0 V ... 10 V. Automated switchover depending on the con-
nected load, or permanently adjustable.
Invertible output signals: 20 mA ... 4 mA / 10 V ... 0 V
Load resistance R
with current output < 600 ohm
A
Load resistance R
with voltage output > 3 kohm
A
LCD with LED backlighting (green/red), can be rotated electronically by 180°
Pressure display: 4 digits, 16 segments
Option of switching between pressure units in the display: bar, MPa, kPa, psi, and inHg
Update: 1,000, 500, 200, and 100 ms (programmable)
≤ ± 0.5% of the range (Best Fit Straight Line, BFSL) as per IEC 61298-2
≤ ± 1.5% of the range
≤ ± 2.0% of the range incl. temperature error
(inclusive of non-linearity, hysteresis, zero-point and full-scale error (corresponds to
error of measurement as per IEC 61298-2))
≤ ± 0.2% of the range
10 °C ... +60 °C
8017612/14NK / 8/2/2019 | PAC50
Subject to change without notice
PAC50