9. ERROR MESSAGE, ANOMALIES, CAUSES, REMEDIES

This equipment has a failure control system. In the event of a failure, error messages may be displayed.
Error message
DEFAUT THERMIQUE
DEFAUT SECTEUR
TOUCHE APPUYEE
60
Translation of the original
instructions
Info machine
Soft gene
Hard gene
Pistolet
Soft pistolet
Hard pistolet
Meaning
Generator thermal pro-
tection.
Mains voltage fault.
Keyboard fault.
V3.0
V1.0
200-350
V3.0
V7.0
Causes
Duty cycle exceeded.
Mains voltage out of tole-
rance or missing a phase.
A key on the keyboard is
pressed when the product
starts up.
ARCPULL 350
Remedies
Wait for the message to go out to
resume welding.
Have your electrical installa-
tion checked by an authorized
person. Reminder the station is
designed to operate on a single-
phase 208-240 Vac 50/60 Hz
network
Have the keyboard checked by
qualified personnel.