Parameter Value Display; Meaning Of The Different Parameters - SOMFY ELIXO 3S M io Manuel D'installation

Masquer les pouces Voir aussi pour ELIXO 3S M io:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Elixo 3S M io
Press ...
I ncrease/reduce the parameter value:
• short press = normal scroll through individual values
• press and hold = scroll rapidly through values
L
Press SET to exit the parameter setting menu.

7.2. Parameter value display

If the display is fixed, the displayed value is the value selected for this
parameter.
If the display is flashing, the displayed value is a selectable value for this
parameter.
7.3. Meaning of the different parameters
(Text in bold = default values)
P01
Complete cycle operating mode
0: sequential
Values
1: sequential + timed close
2: semi-automatic
3: automatic
4: automatic + cell blocking
5: deadman's control (wire)
Comments
P01 =0: Each press on the remote control causes the
motor to move (initial position: gate closed) as per the
following cycle: open, stop, close, stop, open, etc.
P01 =1: Operation in automatic closing mode is only
authorised if the photoelectric cells are fitted and P07=2
or 3.
In sequential mode with automatic timed close:
• the gate closes automatically after the time delay
programmed in parameter "P02",
• pressing a button on the remote control interrupts the
movement taking place and the timed close (the gate
remains open).
P01 =2: In semi-automatic mode:
• pressing the button on the remote control while the
gate is opening will stop the gate,
• pressing a button on the remote control during closing
causes it to reopen.
P01 = 3: Operation in automatic closing mode is only au-
thorised if the photoelectric cells are fitted and P07=2 or 3
This operating mode is not compatible with remote
control using a TaHoma unit.
In automatic closure mode:
• the gate closes automatically after the time delay
programmed in parameter "P02",
• pressing a button on the remote control during open-
ing has no effect,
• pressing a button on the remote control during closing
causes it to reopen,
• pressing a button on the remote control during the
closing time delay restarts the time delay (the gate will
close when the new time delay has elapsed).
If there is an obstacle in the cells' detection zone, the gate
will not close. It will close once the obstacle is removed.
Copyright © 2017 SOMFY ACTIVITES SA. All rights reserved.
to...
P01 = 4: Operation in automatic closing mode is only
authorised if the photoelectric cells are fitted and P07=2
or 3.
This operating mode is not compatible with remote
control using a TaHoma unit.
After the gate is opened, movement in front of the cells
(safe closure) will close the gate after a short time delay
(fixed at 2 seconds).
If there is no movement in front of the cells, the gate will
close automatically after the timed close programmed in
parameter "P02".
If there is an obstacle in the cells' detection zone, the gate
will not close. It will close once the obstacle is removed.
P01 = 5: In wired deadman mode:
• the gate can only be controlled by continuous action
on a wired control,
• the radio controls are inactive.
Automatic closing time delay in complete operating
P02
mode
Values
0 to 30 (value x 10 s = time delay value)
2: 20 s
Comments
If value 0 is selected, the gate immediately closes auto-
matically.
P03
Pedestrian cycle operating mode
0: identical to complete cycle operating mode
Values
1: without automatic closing
2: with automatic closing
Comments
The pedestrian cycle operating mode parameters can
only be set if P01 = 0 to 2.
The P03 = 2 operating mode is not compatible with
remote control using a TaHoma unit.
P03 =0: Pedestrian cycle operating mode is identical to
the complete cycle operating mode selected.
P03 =1: The gate does not close automatically following a
pedestrian opening command.
P03 = 2: Operation in automatic closing mode is only
authorised if the photoelectric cells are fitted. i.e. P07=2
or 3.
Irrespective of the value of P01, the gate does not close
automatically following a pedestrian opening command.
The automatic closing time delay can be programmed in
parameter "P04" (short time delay) or parameter "P05"
(long time delay).
P04
Short automatic closing time delay in pedestrian cycle
Values
0 to 30 (value x 10 s = time delay value)
2: 20 s
Comments
If value 0 is selected, the gate immediately closes auto-
matically.
P05
Long automatic closing time delay in pedestrian cycle
Values
0 to 99 (value x 5 min. = time delay value)
0: 0 min
Comments
Value 0 must be selected if the short automatic closing
time delay in pedestrian cycle is active.
EN