LOCKING THE PROGRAMMING
BUTTONS - FIG. 37
Warning
The keypad must be locked to ensure user safety.
Failure to follow this instruction may result in serious injury, e.g. due to
crushing by the gate.
Locks the programming (end limits, auto-programming, parameter set-
tings).
When the programming buttons are locked, a dot appears after the 1st
digit.
Pressing the "SET", "+", "-" buttons:
• - the "SET" button must be pressed first.
• the "+" and "-" buttons must be pressed simultaneously within 2
seconds.
To access programming again, repeat the same procedure.
11.

DIAGNOSTICS

11.1.

Operating codes display

Code
Designation
C1
Awaiting command
C2
Gate opening
C3
Awaiting gate closure
C4
Gate closing
C6
Detection in progress
for cell safety
C7
Detection in progress
for safety edge safety
C8
Detection in progress
for programmable
safety
C9
Detection in progress
for emergency stop
safety
C12
Reinjecting current
C13
Safety device autotest
in progress
C14
Permanent complete
opening wire control
input
C15
Permanent pedestrian
opening wire control
input
BUS cell programming
C16
refused
Cc1
9.6 V power supply
Cu1
24 V power supply
Copyright © 2017 SOMFY ACTIVITES SA. All rights reserved.
Comments
Automatic closing time delay P02, P04 or
P05 in progress.
Displayed during a movement request or
during movement when detection is in
progress on the safety input.
The display appears for as long as detec-
tion is in progress on the safety input.
Displayed while the autotest is running
on the safety devices.
Indicates that the complete opening wire
control input is permanently activated
(contact closed). Commands coming
from the radio remote controls are then
disabled.
Indicates that the pedestrian opening
wire control input is permanently activat-
ed (contact closed). Commands coming
from the radio remote controls are then
disabled.
Check that the BUS cells (wiring, align-
ment, etc.) are operating correctly
Displayed during operation with 9.6 V
backup battery
Displayed during operation with 24 V
backup battery
11.2.

Programming codes display

Code
Designation
H0
Awaiting setting
Hc1
Awaiting setting + 9.6
V power supply
Hu1
Awaiting setting + 24
V power supply
H1
Awaiting start of
auto-programming
H2
Auto-programming
mode - opening
H4
Auto-programming
mode - closing
F0
Awaiting remote
control memorisa-
tion for operation
in complete opening
mode
F1
Awaiting remote
control memorisa-
tion for operation in
pedestrian opening
mode
F2
Awaiting remote
control memori-
sation for remote
lighting control
F3
Awaiting remote
control memori-
sation for auxiliary
output control
Comments
Pressing and holding the "SET" button for 2
seconds starts auto-programming mode.
Displayed during operation with 9.6 V
backup battery
Displayed during operation with 24 V
backup battery
Pressing the "OK" button starts the au-
to-programming cycle.
Pressing the "+" or "-" button allows the
motor to be controlled in forced operation
mode.
Pressing a button on the remote control
allocates this button to the motor com-
plete opening control.
Pressing "PROG" once more switches to
"awaiting remote control memorisation for
operation in pedestrian opening mode: F1".
Pressing a button on the remote control
allocates this button to the motor pedes-
trian opening control.
Pressing "PROG" once more switches to
"awaiting remote lighting control memo-
risation: F2".
Pressing a button on the remote control
allocates this button to the remote lighting
control.
Pressing "PROG" once more switches to
"awaiting auxiliary output control memo-
risation: F3".
Pressing a button on the remote control
allocates this button to the remote lighting
control.
Pressing "PROG" once more switches to
"awaiting remote control memorisation
for operation in complete opening mode:
F0".