11.3.

Error and breakdown codes display

Code
Designation
E1
Cell safety auto-
The cell autotest is not
test fault
satisfactory.
E2
Programmable
The programmable
safety autotest
safety input autotest is
fault
not satisfactory.
E3
Defective safety
The safety edge auto-
edge autotest
test is not satisfactory.
E4
Obstacle detection when opening
E5
Obstacle detection when closing
E6
Cell safety fault
E7
Safety edge safe-
ty fault
Detection in progress
on safety input for
longer than 3 minutes.
E8
Programmable
safety fault
E10
Motor short-cir-
cuit protection
E11
24 V power
Short circuit protec-
supply short
tion for input/outputs:
protection
product and additional
devices connected to
terminals 21 to 26 (or-
ange light, photoelec-
tric cells (except BUS),
code keypad, safety
edge) not operating
E12
Motor auto-test
The motor auto-tests
fault
are not satisfactory.
E13
Accessories pow-
The accessories power
er supply fault
supply cuts out follow-
ing an overload (exces-
sive consumption)
E15
Fault when the
motor supplied
by the backup
battery is first
switched on
For all other fault and breakdown codes, please contact Somfy.
11.4.

Access to memorised data

To access memorised data, select the parameter "Ud" then press "OK".
13
Comments
Solution?
Check that "P07" is
correctly configured.
Check the wiring of
the cells.
Check that "P09" is
correctly configured.
Check the program-
mable safety input
wiring.
Check that "P08" is
correctly configured.
Check the safety edge
wiring.
Check that no obsta-
cles are causing the
cells or safety edge to
detect.
Check that "P07",
"P08" or "P09" is
correctly configured in
relation to the device
connected to the
safety input.
Check the safety device
wiring.
Check that the pho-
toelectric cells are
correctly aligned.
Check the motor
wiring.
Check the wiring, then
disconnect the power
supply for 10 seconds.
N.B.: maximum acces-
sories consumption
= 1.2 A
Request a gate move-
ment.
If the fault is still pres-
ent, contact Somfy.
N.B.: maximum acces-
sories consumption
= 1.2 A
Check the consump-
tion of the connected
accessories.
Disconnect the backup
battery and connect
the motor to the mains
to switch it on for the
first time.
Data
U0 to U1
Complete
opening cycle
counter
U2 to U3
U6 to U7
Cycle counter
with obstacle
detection
U8 to U9
Pedestrian opening cycle counter
U12 to U13
Reset movement counter
U14 to U15
Number of remote controls memorised for complete
U20
opening control
Number of remote controls memorised for pedestrian
U21
opening control
Number of remote controls memorised for remote
U22
lighting control
Number of remote controls memorised for auxiliary
U23
output control
Log of the last 10 faults (d0 most recent - d9 oldest)
d0 to d9
To clear the fault log: press and hold "OK" for 7 s.
dd
Designation
global [hundreds of thousands - tens
of thousands - thousands] [hun-
dreds - tens - units]
since last auto-programming
[hundreds of thousands - tens of
thousands - thousands] [hundreds -
tens - units]
global [hundreds of thousands - tens
of thousands - thousands] [hun-
dreds - tens - units]
since last auto-programming
[hundreds of thousands - tens of
thousands - thousands] [hundreds -
tens - units]
Copyright © 2017 SOMFY ACTIVITES SA. All rights reserved.