Connecting Additional Devices; General Wiring Diagram; Parameter Setting For Wiring Options - SOMFY ROLLIXO io Manuel D'installation

Masquer les pouces Voir aussi pour ROLLIXO io:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Rollixo io

CoNNECtING ADDItIoNAL DEvICEs

General wiring diagram

L1
1
2
terminal
type of terminal
1
Earth
2
L1
3
Neutral
4
L2
5
Contact
6
Shared
7
Contact
8
12 Vdc
9
0 Vdc
10
Contact
11
Shared
12
24 Vdc
13
0 Vdc
14
24 Vdc
15
0 Vdc
16
24 Vdc
17
0 Vdc
18
Shared
19
Contact
20
Test output
22

Parameter setting for wiring options

Dipswitch Possible parameter setting
1
Cell self-test
2
Choice of cell type
3
Orange light 2s warning
4
Choice of wired safety edge type
5
Alarm operation
6
Do not use
12
Stop
Safety Edge
M
Sec
N
L2
3
4
5
6
7
8
R
Connection
RDO CSI 50 or 60 motor
Fall protection - NC contact
Safety edge safety input
12 Vdc safety edge power supply
NO contact
24V - 3.5 W orange light output
TX cell 24 V power supply
RX cell 24 V power supply
Cell safety input (NC)
Cell safety test output
433.42 MHz aerial
oN
Activated
Photoelectric
Activated
Resistive
Activated
KeySwitch
Flash
24V dc
24V Cell
9
10
11
12
13
14
15
16
17
24 Vdc
Comments
Wired resistive safety edge (terminals 7 - 8)
Wired optical safety edge (terminals 7 - 8 - 9)
Maximum 4 W bulb
Transmitting photoelectric cell/Reflex photocell power supply
Receiving photoelectric cell power supply
Reflex photocell self-test
Do not connect an offset aerial (incompatible)
off
Deactivated
Electric eye
Deactivated
Optical
Deactivated
Test
Sec Cell
Sec
Ant
18
19
20
22
Aerial
Antenne
1
2
3
4
STOP
Prog
Copyright © 2012 Somfy SAS. All rights reserved

Publicité

Chapitres

Table des Matières
loading

Table des Matières