C H E C K I N G
B AT T E RY
LEVEL
To check the battery fluid level:
Remove the battery case, see page 65
u
(EXTRACTING THE BATTERY CASE).
Make sure that battery fluid level is
u
between the "MIN" and "MAX" marks on
the battery.
If not so:
Top up with distilled water only. Do not
exceed the "MAX" mark, because
battery fluid expands when the battery
is under charging.
Add distilled water until achieving correct
u
level.
66
use and maintenance Scarabeo 250
CHARGING THE BATTERY
Remove
the
u
(REMOVING THE BATTERY).
Remove the battery caps.
u
Check electrolyte level, see on the side
u
(CHECKING BATTERY FLUID LEVEL).
Connect the battery to a battery charger.
u
Recommended charge rate is 1/10th of
u
battery capacity.
After charging the battery, check battery
u
fluid level again and top up with distilled
water if needed.
Refit the caps.
u
F L U I D
When you di sconn ect the battery
charger, allow 5-10 minutes before
refitting the battery, as it will keep
producing gas for a few minutes.
battery,
see
page 65
INSTALLING THE BATTERY
u
u
u
Always connect the battery breather
pipe, to prevent the sulfuric acid
vapours from corroding the electric
system, painted parts, rubber elements
or gaskets when they exit the breather
pipe itself.
u
u
u
Remove the battery case, see page 65
(EXTRACTING THE BATTERY CASE).
Refit the battery into its mount.
Refit the battery breather pipe (1).
Connect first the positive (+) and then
the negative cable (-).
Coat the terminals of cables and battery
with neutral grease or Vaseline.
Refit the battery case, see page 65
(EXTRACTING THE BATTERY CASE).