7.3 Hardware configuration
Hardware configuration is only required
if you wish to activate communication via
serial telemetry. (11.1 How to switch from
ONVIF communication mode to RS-485
(telemetry) mode, page 43).
7.3.1 Opening the configuration door
Before powering the device it must be configured
correctly by setting the dip-switches inside the
configuration hatch. Open the hatch by undoing the
screws as shown in figure.
Fig. 55
7.3.2 Configuration of the dip-switches
Once the configuration cover is opened the dip-
switches will appear as shown in figure.
Fig. 56
7.3.3 DIP1 configuration
When the dip-switch rocker is up it
represents the value 1 (ON). When the
dip-switch rocker is down it represents the
value 0 (OFF).
Dip-switch 1 is used to update the firmware.
Fig. 57
MNVCUPTMAXIR_1430_EN
DIP1 CONFIGURATION
Description
SW
SW
4
3
Baud rate
OFF OFF OFF –
adjustment
ON
OFF OFF –
OFF ON
ON
ON
OFF OFF ON
ON
OFF ON
OFF ON
ON
ON
Firmware update –
–
–
–
Tab. 8
7.3.4 DIP2 configuration
When the dip-switch rocker is up it
represents the value 1 (ON). When the
dip-switch rocker is down it represents the
value 0 (OFF).
Video positioning systems of the P&T can be
controlled by a range of protocols.
Fig. 58
DIP2 CONFIGURATION
SW
8
PTZ Manager
OFF OFF OFF OFF OFF OFF OFF OFF
MACRO (VIDE-
OFF OFF OFF OFF OFF ON ON ON
OTEC)
PANASONIC
OFF OFF OFF ON OFF ON OFF OFF
PELCO D
OFF OFF OFF OFF ON OFF OFF ON
AMERICAN DYNA-
OFF OFF OFF OFF ON ON ON OFF
MICS
VISTA
OFF OFF OFF ON OFF OFF ON ON
Tab. 9
SW
SW
Configuration
2
1
300 baud
600 baud
OFF –
1200 baud
OFF –
2400 baud
–
4800 baud
–
9600 baud
ON
–
19200 baud
ON
–
38400 baud
–
ON
Set up enabled
–
OFF Set up disabled
SW
SW
SW
SW
SW
SW
7
6
5
4
3
2
SW
1