Hardware Configuration; Opening The Configuration Door; Configuration Of The Dip-Switches; Dip1 Configuration - Videotec ULISSE MAXI NETCAM Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7.3 Hardware configuration

Hardware configuration is only required
if you wish to activate communication via
serial telemetry. (11.1 How to switch from
ONVIF communication mode to RS-485
(telemetry) mode, page 43).

7.3.1 Opening the configuration door

Before powering the device it must be configured
correctly by setting the dip-switches inside the
configuration hatch. Open the hatch by undoing the
screws as shown in figure.
Fig. 55

7.3.2 Configuration of the dip-switches

Once the configuration cover is opened the dip-
switches will appear as shown in figure.
Fig. 56

7.3.3 DIP1 configuration

When the dip-switch rocker is up it
represents the value 1 (ON). When the
dip-switch rocker is down it represents the
value 0 (OFF).
Dip-switch 1 is used to update the firmware.
Fig. 57
MNVCUPTMAXIR_1430_EN
DIP1 CONFIGURATION
Description
SW
SW
4
3
Baud rate
OFF OFF OFF –
adjustment
ON
OFF OFF –
OFF ON
ON
ON
OFF OFF ON
ON
OFF ON
OFF ON
ON
ON
Firmware update –
Tab. 8

7.3.4 DIP2 configuration

When the dip-switch rocker is up it
represents the value 1 (ON). When the
dip-switch rocker is down it represents the
value 0 (OFF).
Video positioning systems of the P&T can be
controlled by a range of protocols.
Fig. 58
DIP2 CONFIGURATION
SW
8
PTZ Manager
OFF OFF OFF OFF OFF OFF OFF OFF
MACRO (VIDE-
OFF OFF OFF OFF OFF ON ON ON
OTEC)
PANASONIC
OFF OFF OFF ON OFF ON OFF OFF
PELCO D
OFF OFF OFF OFF ON OFF OFF ON
AMERICAN DYNA-
OFF OFF OFF OFF ON ON ON OFF
MICS
VISTA
OFF OFF OFF ON OFF OFF ON ON
Tab. 9
SW
SW
Configuration
2
1
300 baud
600 baud
OFF –
1200 baud
OFF –
2400 baud
4800 baud
9600 baud
ON
19200 baud
ON
38400 baud
ON
Set up enabled
OFF Set up disabled
SW
SW
SW
SW
SW
SW
7
6
5
4
3
2
SW
1
31

Publicité

Table des Matières
loading

Table des Matières