7.3.5 DIP3 configuration
When the dip-switch rocker is up it
represents the value 1 (ON). When the
dip-switch rocker is down it represents the
value 0 (OFF).
Fig. 59
7.3.5.1 Address configuration
It is possible to set the pan & tilt address: from 1 to
255. Binary code is used to select the address, using
the dip-switches (17 Address table, page 52).
7.3.5.2 Setting of the serial communication
lines
The product is provided with the following serial
communication lines:
• RS-485: 1 line
• RS-232: 1 line
The serial lines configuration must be carried on
through the following dip-switches:
• DIP 3: SW 9-SW 10
DIP3 CONFIGURATION
SW
SW
SW
Configuration
10
9
8-1
OFF
OFF
–
It allows the one-way communication
on RS-485-1 line. It allows the two-ways
communication on RS-232 line.
ON
ON
–
It allows the two-ways, half-duplex,
communication on RS-485-1 line.
Tab. 10
32
7.3.6 DIP4 configuration
Unlike the previous cases in this table when
the dip-switch rocker is up it represents the
value 0 (OFF) while if the rocker is down it
represents the value 1 (ON).
Fig. 60
DIP4 CONFIGURATION
Description
SW 2
Factory default
–
–
RS-485-1 line
ON
OFF
Tab. 11
SW 1
Configuration
ON
Enabled
OFF
Disabled
–
Terminated
–
Not terminated
MNVCUPTMAXIR_1430_EN