8.11 Hardware configuration
Hardware configuration is only required
if you wish to activate communication via
serial telemetry. (12.1 How to switch from
ONVIF communication mode to RS-485
(telemetry) mode, page 42).
8.11.1 Opening the configuration door
Before powering the device it must be configured
correctly by setting the dip-switches inside the
configuration window. Open the hatch by undoing
the screws as shown in figure.
Fig. 43
The DIP-switches appear as shown in the figure.
Fig. 44
After installation and wiring, close the
product again.
8.11.2 DIP1 configuration
When the switch rocker is up it represents
the value 1 (ON). When the dip-switch
rocker is down it represents the value 0
(OFF).
Switch 1 is used to update the firmware.
Fig. 45
MNVCUPT3_1511_EN
DIP1 CONFIGURATION
Description
SW
SW
4
3
Baud rate
OFF OFF OFF –
adjustment
ON
OFF OFF –
OFF ON
ON
ON
OFF OFF ON
ON
OFF ON
OFF ON
ON
ON
Firmware
–
–
update
–
–
Tab. 9
8.11.3 DIP2 configuration
When the switch rocker is up it represents
the value 1 (ON). When the dip-switch
rocker is down it represents the value 0
(OFF).
The Pan & Tilt can be controlled via various protocols.
Fig. 46
DIP2 CONFIGURATION
Protocol
SW
SW
8
7
PTZ Manager1
OFF OFF OFF OFF OFF OFF OFF OFF
MACRO
OFF OFF OFF OFF OFF ON ON ON
(VIDEOTEC)
PANASONIC
OFF OFF OFF ON OFF ON OFF OFF
PELCO D
OFF OFF OFF OFF ON OFF OFF ON
AMERICAN
OFF OFF OFF OFF ON ON ON OFF
DYNAMICS
VISTA
OFF OFF OFF ON OFF OFF ON ON
Tab. 10
Deafult configuration: MACRO (VIDEOTEC), 115200
1
baud, RS-232, Address 1. This option does not require
the setting of the DIP-switch (DIP1, DIP3).
Tab. 11
SW
SW
Baud rate
2
1
300 baud
600 baud
OFF –
1200 baud
OFF –
2400 baud
–
4800 baud
–
9600 baud
ON
–
19200 baud
ON
–
38400 baud
–
ON
Set up enabled
–
OFF Set up disabled
SW
SW
SW
SW
SW
6
5
4
3
2
SW
1
29