6.9 Hardware configuration
Hardware configuration is only necessary
when using analog units.
6.9.1 Opening the configuration door
Before powering the device it must be configured
correctly by setting the dip-switches inside the
configuration window. Open the hatch by undoing
the screws as shown in figure.
Fig. 22
The DIP-switches appear as shown in the figure.
Fig. 23
After installation and wiring, close the
product again.
6.9.2 DIP1 configuration
When the switch rocker is up it represents
the value 1 (ON). When the dip-switch
rocker is down it represents the value 0
(OFF).
Switch 1 is used to update the firmware.
Fig. 24
18
DIP1 CONFIGURATION
Description
SW
SW
4
3
Baud rate
OFF
OFF
adjustment
ON
OFF
OFF
ON
OFF
ON
OFF
ON
Firmware update
–
–
Tab. 6
6.9.3 DIP2 configuration
When the switch rocker is up it represents
the value 1 (ON). When the dip-switch
rocker is down it represents the value 0
(OFF).
The Pan & Tilt can be controlled via various protocols.
Fig. 25
DIP2 CONFIGURATION
Protocol
SW
SW
8
7
PTZ Manager1
OFF OFF OFF OFF OFF OFF OFF OFF
MACRO
OFF OFF OFF OFF OFF ON
(VIDEOTEC)
PANASONIC
OFF OFF OFF ON
PELCO D
OFF OFF OFF OFF ON
AMERICAN
OFF OFF OFF OFF ON
DYNAMICS
VISTA
OFF OFF OFF ON
Tab. 7
Configuration line RS232: MACRO (VIDEOTEC), 115200
1
baud, Address 1. This option does not require the
setting of the DIP-switch (DIP1, DIP3).
SW
SW
Baud rate
2
1
OFF
–
300 baud
OFF
–
600 baud
ON
OFF
–
1200 baud
ON
OFF
–
2400 baud
OFF
ON
–
4800 baud
OFF
ON
–
9600 baud
ON
ON
–
19200 baud
ON
ON
–
38400 baud
–
–
ON
Set up enabled
–
–
OFF
Set up disabled
SW
SW
SW
SW
SW
6
5
4
3
2
ON
OFF ON
OFF OFF
OFF OFF ON
ON
ON
OFF OFF ON
MNVCUPKT_1838_EN
SW
1
ON
OFF
ON