7.2.3.2 24Vac power line connection
Power the device with an SELV type, 24Vac,
8A isolated source derived from a double
isolation UL Listed transformer specially
protected in output. Alternatively, use the
power supply and control kit (UPTIRPS120).
24Vac
GND
a
Fig. 31
Connect the power supply cables as described in the
table below.
CONNECTION OF THE POWER SUPPLY LINE
Colour
Power supply 24Vac
Defined by the installer
Defined by the installer
Yellow/Green
Tab. 4
22
CN1
24Vac
Terminals
24Vac
24Vac
GND
7.2.3.3 120/230Vac power line connection
To connect the power supply line use the
appropriate junction-box (UPTJBUL). For
further information, refer to the product
use and installation manual.
N
GND
a
Fig. 32
Connect the power supply cables as described in the
table below.
CONNECTION OF THE POWER SUPPLY LINE
Colour
Power supply 230Vac
Blue
Brown
Yellow/Green
Power supply 120Vac
Blue
Brown
Yellow/Green
Tab. 5
CN1
L
Terminals
N (Neutral)
L (Phase)
GND
N (Neutral)
L (Phase)
GND
MNVCUPTMAXIR_1430_EN