Available set-up
G-H
parameters
Gas-High - increase in the gas post-flow time at maximum welding amperage
(continued)
unit
setting range
factory setting
The value set for G-H only applies if the maximum welding current really has been set.
The actual value is derived from the instantaneous welding amperage. With a medium
welding amperage, for example, the actual value will be one-half of the value set for G-
H.
Important! The values for the set-up parameters G-L and G-H are added together. For
example, if both parameters are on maximum (40 s), the gas post-flow will last:
-
-
-
If Aut is selected, the gas post-flow time G-H is calculated automatically. This takes the
selected process (AC or DC welding) into account.
Fig.18 Gas post-flow time as a function of the welding amperage
GPU
Gas Purger - Purging of shielding gas
Unit
Setting range
Factory setting
Purging of the shielding gas begins as soon as GPU is allocated a value.
For safety reasons, purging of the shielding gas cannot be restarted until a new GPU
value is entered.
Important! Purging with shielding gas is necessary if condensation forms when the
device is left unused in a cold environment for a prolonged period. Long hosepacks are
most affected.
s
0 - 40 / Aut
Aut
40 s at minimum welding amperage
80 s at maximum welding amperage
60 s where the welding amperage is e.g. exactly half of the maximum
t
G-H
G-L
I
min
min
OFF/0.1 - 10.0
OFF
welding amperage at any
given moment
36
I
I
max